Failure rate and conductor externalization in the Biotronik Linox/Sorin Vigila implantable cardioverter-defibrillator lead
F Noti, A Lam, N Klossner, J Seiler, H Servatius… - Heart Rhythm, 2016 - Elsevier
Background We observed a case of conductor externalization in a Biotronik Linox lead.
Objective The purpose of this study was to investigate lead performance of the Linox lead …
Objective The purpose of this study was to investigate lead performance of the Linox lead …
[HTML][HTML] Ticagrelor therapy and atrioventricular block: do we need to worry?
E De Maria, A Borghi, L Modonesi… - World Journal of Clinical …, 2017 - ncbi.nlm.nih.gov
Ticagrelor is a potent, direct P2Y12 antagonist with rapid onset of action and intense platelet
inhibition, indicated in patients with acute coronary syndromes (ACS). This drug is usually …
inhibition, indicated in patients with acute coronary syndromes (ACS). This drug is usually …
First time description of early lead failure of the Linox Smart lead compared to other contemporary high-voltage leads
V Weberndörfer, T Nyffenegger, I Russi… - Journal of Interventional …, 2018 - Springer
Purpose Early lead failure has recently been reported in ICD patients with Linox SD leads.
We aimed to compare the long-term performance of the following lead model Linox Smart …
We aimed to compare the long-term performance of the following lead model Linox Smart …
Insulation failure and externalized conductor of a single-coil Kentrox lead: an ongoing story?
H Bogossian, D Mijic, G Frommeyer… - Journal of …, 2015 - search.ebscohost.com
Abstract Externalized Conductor of a Single-Coil Kentrox Lead Conductor externalization is
a frequent complication with the St. Jude Medical Riata lead. Single case reports also …
a frequent complication with the St. Jude Medical Riata lead. Single case reports also …
[HTML][HTML] Externalized conductors and insulation failure in Biotronik defibrillator leads: History repeating or a false alarm?
E De Maria, A Borghi, L Bonetti… - World Journal of …, 2017 - ncbi.nlm.nih.gov
Conductor externalization and insulation failure are frequent complications with the recalled
St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor …
St. Jude Medical Riata implantable cardioverter-defibrillator (ICD) leads. Conductor …
Externalized conductor of a Kentrox lead and an unexpected insulation failure
JJ Eulert-Grehn, V Falk… - … and Thoracic Surgery, 2019 - academic.oup.com
Cardiac resynchronization therapy-defibrillator device upgrades may represent a
challenging scenario, especially because unexpected findings can increase procedure …
challenging scenario, especially because unexpected findings can increase procedure …
[PDF][PDF] CARDIAC ARRHYTHMIAS
MM REFAAT, R COSTA, JI WANG… - Lebanese Medical …, 2019 - researchgate.net
Objectives: The Evolution mechanical dilator sheath (Cook Medical) uses a rotational
mechanism and a bladed tip to overcome fibrosis around cardiovascular implantable …
mechanism and a bladed tip to overcome fibrosis around cardiovascular implantable …
Occurrence and extraction of implantable cardioverter-defibrillator leads with conductor externalization
A Maciąg, P Syska, M Sterliński… - Cardiology …, 2018 - journals.viamedica.pl
Background: The increasing number of patients with implantable cardioverter-defibrillators
(ICD) contributes to the rising number of patients qualifying for a transvenous lead extraction …
(ICD) contributes to the rising number of patients qualifying for a transvenous lead extraction …
Multiple inappropriate defibrillator shocks due to insulation failure of a Biotronik Linox defibrillator lead with externalized conductor
H Elfarra, R Moosdorf, L Rybinski, W Grimm - Herzschrittmachertherapie+ …, 2016 - Springer
In diesem Beitrag wird über einen Patienten mit insgesamt 35 inadäquaten
Defibrillatorschocks aufgrund eines Isolationsdefekts einer Biotronik-Linox®-Elektrode mit …
Defibrillatorschocks aufgrund eines Isolationsdefekts einer Biotronik-Linox®-Elektrode mit …
Long-Range Real Migration of Implantable Cardioverter Defibrillator Lead
A Keyser, H Brodoefel, C Schmid - The Thoracic and …, 2016 - thieme-connect.com
The need for pacemaker and implantable cardioverter defibrillator (ICD) lead revisions and
extractions is steadily increasing. Despite the lack of representative studies, the risk of lead …
extractions is steadily increasing. Despite the lack of representative studies, the risk of lead …