Hip implants VII: Finite element analysis and optimization of cross-sections

AL Sabatini, T Goswami - Materials & Design, 2008 - Elsevier
Several hip stems were re-evaluated in this paper. Finite element analysis was conducted
for each of the stems with various cross-sections applied to them. Comparison of von Mises …

Finite element modelling and fatigue life assessment of a cemented total hip prosthesis based on 3D scanning

M Babić, O Verić, Ž Božić, A Sušić - Engineering Failure Analysis, 2020 - Elsevier
Fatigue life of a loosened total hip prosthesis femoral component cemented into bone was
investigated assuming loads specified by the standard ISO 7206-4. The total hip prosthesis …

Fracture analysis of a total hip prosthesis based on reverse engineering

M Babić, O Verić, Ž Božić, A Sušić - Engineering Fracture Mechanics, 2019 - Elsevier
A reverse engineering procedure based on optical 3D scanning was implemented to
generate a total hip prosthesis CAD model needed to create the finite element model of the …

Design of new generation femoral prostheses using functionally graded materials: a finite element analysis

AA Oshkour, NA Abu Osman, YH Yau… - Proceedings of the …, 2013 - journals.sagepub.com
This study aimed to develop a three-dimensional finite element model of a functionally
graded femoral prosthesis. The model consisted of a femoral prosthesis created from …

Micro-mechanical modeling of the cement–bone interface: the effect of friction, morphology and material properties on the micromechanical response

D Janssen, KA Mann, N Verdonschot - Journal of biomechanics, 2008 - Elsevier
In order to gain insight into the micro-mechanical behavior of the cement–bone interface, the
effect of parametric variations of frictional, morphological and material properties on the …

The mechanical effects of different levels of cement penetration at the cement–bone interface

D Waanders, D Janssen, KA Mann… - Journal of …, 2010 - Elsevier
The mechanical effects of varying the depth of cement penetration in the cement–bone
interface were investigated using finite element analysis (FEA) and validated using …

Finite element analysis on longitudinal and radial functionally graded femoral prosthesis

AA Oshkour, NA Abu Osman… - … journal for numerical …, 2013 - Wiley Online Library
This study focused on developing a 3D finite element model of functionally graded femoral
prostheses to decrease stress shielding and to improve total hip replacement performance …

Acrylic bone cements: influence of time and environment on physical properties

M Nottrott - Acta Orthopaedica, 2010 - Taylor & Francis
Acrylic bone cements are in extensive use in joint replacement surgery. They are weight
bearing and load transferring in the bone-cement-prosthesis complex and therefore, inter …

Finite element simulation of cement‐bone interface micromechanics: A comparison to experimental results

D Janssen, KA Mann… - Journal of Orthopaedic …, 2009 - Wiley Online Library
Recently, experiments were performed to determine the micromechanical behavior of the
cement‐bone interface under tension‐compression loading conditions. These experiments …

Finite element analysis of circumferential crack behavior in cement–femoral prosthesis interface

AA Oshkour, MM Davoodi, NAA Osman, YH Yau… - Materials & Design, 2013 - Elsevier
Investigating the crack behavior in the cement mantle can improve total hip replacement
performance by lessening the effects of crack failure and femoral prosthesis loosening. This …