A brief review of power quality issues in smart grid and a simple user friendly software

MH Sazli, İ Koşalay… - 2018 6th International …, 2018 - ieeexplore.ieee.org
Investigations of power quality can be performed for every stages of power systems, ie low,
medium and high voltage levels. Power quality disturbances at low voltage levels are mainly …

A comprehensive control strategy of railway power quality compensator for AC traction power supply systems

HJ Kaleybar, S Farshad - Turkish Journal of Electrical …, 2016 - journals.tubitak.gov.tr
The development of electrical railway systems leads to critical power quality problems in the
power grid. This paper discusses a kind of half-bridge-based railway power quality …

Analysis and design of grid-connected 3-phase 3-level AT-NPC inverter for low-voltage applications

E Avci, M Ucar - Turkish Journal of Electrical Engineering and …, 2017 - journals.tubitak.gov.tr
The 3-level T-type neutral point clamped (T-NPC) inverter has become the most popular
multilevel inverter used in low-voltage applications. However, the realization of a …

Generation of power quality disturbances using MATLAB-Simulink

PV Dhote, BT Deshmukh… - … on Computation of …, 2015 - ieeexplore.ieee.org
Analysis of PQ (Power Quality) signals for detecting PQ disturbances are one of the major
challenging techniques being explored by many researchers. It becomes important to …

A new hysteresis band current control technique for a shunt active filter

M Kale, E ÖZDEMİR - Turkish Journal of Electrical …, 2015 - journals.tubitak.gov.tr
This paper proposes a hysteresis band (HB) current control technique to reduce the power
losses in a shunt active filter. During a switching period in the zero-crossing region, the …

Design and operation of a multifunction photovoltaic power system with shunt active filtering using a single-stage three-phase multilevel inverter

S Sezen, A Aktaş, M Uçar… - Turkish Journal of …, 2017 - journals.tubitak.gov.tr
In this paper, the control of a multifunction grid-connected photovoltaic (PV) system with a
three-phase three-level (3L) neutral point clamped (NPC) inverter is proposed, which can …

[HTML][HTML] Voltage balancing for active power filter using dual-frequency multicarrier modulation with balanced H-bridge control

Y Hoon, H Ahmad - e-Prime-Advances in Electrical Engineering …, 2024 - Elsevier
In this paper, a switching control method integrated with voltage balancing feature is
presented to manage operation of single-phase 5-level cascaded H-bridge (CHB) inverter …

PLL-Less Three-Phase Four-Wire SAPF with STF-dq0 Technique for Harmonics Mitigation under Distorted Supply Voltage and Unbalanced Load Conditions

Y Hoon, MA Mohd Radzi - Energies, 2018 - mdpi.com
This paper presents a non-iterative technique that generates reference current to manage
operation of a three-phase four-wire shunt active power filter which employs a three-leg split …

Adaptive linear neural network approach for three-phase four-wire active power filtering under non-ideal grid and unbalanced load scenarios

Y Hoon, MA Mohd Radzi, AS Al-Ogaili - Applied Sciences, 2019 - mdpi.com
This paper presents the enhancements performed on the adaptive linear neuron (ADALINE)
technique so that it can be applied for active power filtering purposes in a three-phase four …

Shunt active filter for multi-level inverters using DDSRF with state delay controller

CR Rajesh, SP Umayal - Journal of Power Electronics, 2018 - koreascience.kr
The traditional power control theories for the harmonic reduction methods in multilevel
inverters are found to be unreliable under unbalanced load conditions. The unreliability in …