Pre-analytical errors management in the clinical laboratory: a five-year study

AG Marin, F Rivas-Ruiz, M del Mar Pérez-Hidalgo… - Biochemia …, 2014 - hrcak.srce.hr
Sažetak Introduction: This study describes quality indicators for the pre-analytical process,
grouping errors according to patient risk as critical or major, and assesses their evaluation …

[HTML][HTML] Sample management: stability of plasma and serum on different storage conditions

CFY Flores, ÁMH Pineda, VMC Bonilla, K Sáenz-Flor - Ejifcc, 2020 - ncbi.nlm.nih.gov
Materials and methods A total of thirty healthy adults were studied. The serum/plasma
samples were centrifuged at 2000g for 10 minutes. Immediately after centrifugation, the …

[HTML][HTML] Errors of clinical laboratory and its impact on patient safety

EG Lao, ÁS García, MB Figuerola, E Moreno… - Open Journal of Social …, 2017 - scirp.org
The aim of this study is to analyse the potential risks of medical laboratory activities in all
processes: Strategic, operational (pre-preanalytical, preanalytical, analytical, postanalytical …

Factores interferentes de la fase preanalítica que afectan los resultados de exámenes de laboratorio

J Quijada Ravanales, A Ilufiz - 2020 - dspace.utalca.cl
La etapa preanalítica es el inicio del ciclo de procesamiento de una muestra dentro del
laboratorio clínico, compuesto por el paciente quien inicia con la consulta médica, el medico …

Preanalitik süreçte sıcaklık ve zamanın Anti-Echinococcus granulosus antikor titreleri üzerindeki etkilerinin incelenmesi

B Ağacikoğullari - 2022 - search.proquest.com
Kistik ekinokokkozis hastalığı, Echinococcus granulosus adı verilen sestod parazitinneden
olduğu, halk sağlığını tehdit eden önemli bir hastalıktır. İnsanlar rastlantısal arakonaktır …

A study to analyze the pre-Analytical Errors and its management in the clinical laboratory of Rama Medical College.

A Singh, PA Kulkarni, PK Sharma… - European Journal of …, 2023 - search.ebscohost.com
Pre-analytical mistakes have previously been proven to contribute a considerable fraction of
laboratory errors and to a variety of patient safety hazards. Accreditation against ISO 15189 …

Plasma and Serum Sample Stability at Different Storage Conditions with Concentration Variation of Biochemical Analytes

MSA Faruk, MD Prank, MR Pasha - … Plasma and Serum Sample Stability at … - papers.ssrn.com
The stability of the analytes in serum and plasma is crucial for clinical laboratories,
particularly if there is a delay in processing them or if they need to be preserved for future …

[引用][C] Useful links

D Pašalić - Biochemia Medica, 2009

[引用][C] Useful links Events