高压电力电缆护层电流在线监测及故障诊断技术
Y Yuan, H Zhou, J Dong, X Shi… - … Jishu/High Voltage …, 2015 - researchonline.gcu.ac.uk
Cable sheath currents can be utilized to identify cable faults at an early stage and avoid
unplanned power outages. We put forward a methodology to analyze the sheath currents in …
unplanned power outages. We put forward a methodology to analyze the sheath currents in …
Online monitoring and diagnosis of HV cable faults by sheath system currents
Cross-bonded metal sheath connection is applied in sectioned single-core power cables to
reduce or eliminate the voltages that are induced in the sheath over long distances …
reduce or eliminate the voltages that are induced in the sheath over long distances …
Analysis of cable failure modes and cable joint failure detection via sheath circulating current
X Dong, Y Yuan, Z Gao, C Zhou… - 2014 IEEE Electrical …, 2014 - ieeexplore.ieee.org
Power cables are preferred in urban areas for power transmission and distribution because
of their high reliability, environmental friendliness and the visual invisibility. Whilst the …
of their high reliability, environmental friendliness and the visual invisibility. Whilst the …
Applications of artificial intelligence and hybrid neural network methods with new bonding method to prevent electroshock risk and insulation faults in high-voltage …
B Akbal - Neural Computing and Applications, 2018 - Springer
The sheath current causes cable faults and electroshocks in the high-voltage underground
cable lines. Thus, the sheath current must be determined before a new high-voltage cable …
cable lines. Thus, the sheath current must be determined before a new high-voltage cable …
Short‐circuit current difference of parallel strands in winding turns and its influence on the distribution of electromagnetic force
Transformer winding turns often consist of multiple parallel strands. The spatial position
variation of each strand affects the leakage inductance of each branch, resulting in an …
variation of each strand affects the leakage inductance of each branch, resulting in an …
Calculation of induced sheath voltages in power cables–single circuit system versus double circuit system
S Czapp, K Dobrzyński, J Klucznik… - Journal of Information …, 2014 - mostwiedzy.pl
This paper presents comparison of values of induced sheath voltages in power cable
metallic sheaths when one or two cables per phase are used. Calculation of voltages is …
metallic sheaths when one or two cables per phase are used. Calculation of voltages is …
Evaluation of high‐voltage AC cable grounding systems based on the real‐time monitoring and theoretical calculation of grounding currents
Z Li, B Du, W Li - High voltage, 2018 - Wiley Online Library
For high‐voltage (HV) AC cable transmission systems, the metal sheaths of three separate
single‐core cables are cross‐bonded at each end of the cable section, to suppress the …
single‐core cables are cross‐bonded at each end of the cable section, to suppress the …
Safety Issues Referred to Induced Sheath Voltages in High-Voltage Power Cables—Case Study
S Czapp, K Dobrzynski - Applied Sciences, 2020 - mdpi.com
Load currents and short-circuit currents in high-voltage power cable lines are sources of the
induced voltages in the power cables' concentric metallic sheaths. When power cables …
induced voltages in the power cables' concentric metallic sheaths. When power cables …
[PDF][PDF] A proposed method for reduction of induced zero-sequence current in cable system
SAR Salem, RR Eiada, EAG Badran - Int. J. Power Electron. Drive …, 2022 - academia.edu
Zero-sequence circulating currents are particularly problematic because they can
occasionally lead to protective relay failure. However, it is not usually understood that …
occasionally lead to protective relay failure. However, it is not usually understood that …
[PDF][PDF] OSSB and Hybrid Methods to Prevent Cable Faults for Harmonic Containing Networks.
B Akbal - Electronics & Electrical Engineering, 2018 - pdfs.semanticscholar.org
High temperature causes aging of insulation material of high voltage underground cable line
(HVUL), so cable faults occurs. The sheath current (SC) is the most important factor for …
(HVUL), so cable faults occurs. The sheath current (SC) is the most important factor for …