An AHP model for multiple-criteria prioritization of seismic retrofit solutions in gravity-designed industrial buildings
F Andreolli, P Bragolusi, C D'Alpaos… - Journal of building …, 2022 - Elsevier
This paper deals with the development of an Analytic Hierarchy Process (AHP) model aimed
at driving decision-making processes when dealing with seismic retrofitting of industrial …
at driving decision-making processes when dealing with seismic retrofitting of industrial …
Seismic fragility functions of industrial precast building classes
A Babič, M Dolšek - Engineering structures, 2016 - Elsevier
The seismic vulnerability of twelve industrial precast building classes has been investigated
by conducting nonlinear dynamic analyses on sample buildings from these building classes …
by conducting nonlinear dynamic analyses on sample buildings from these building classes …
Modelling and seismic response analysis of non-residential single-storey existing precast buildings in Italy
M Bosio, C Di Salvatore, D Bellotti… - Journal of Earthquake …, 2023 - Taylor & Francis
Old precast buildings are often characterized by poor detailing that may hamper the
structural performance, particularly in the case of earthquakes. This is essentially related …
structural performance, particularly in the case of earthquakes. This is essentially related …
Comparative evaluation of seismic performance and environmental impact of traditional and dissipation-based retrofitting solutions for precast structures
Seismic rehabilitation is crucial to extend the nominal service life and help reduce the
seismic losses of reinforced concrete precast industrial buildings. Along with traditional …
seismic losses of reinforced concrete precast industrial buildings. Along with traditional …
Parametric study on module wall-core system of concrete modular high-rises considering the influence of vertical inter-module connections
High-rise modular buildings are attractive for metropolises, but few applications exist. One
reason is the lack of relevant knowledge about their lateral force resistance. Existing high …
reason is the lack of relevant knowledge about their lateral force resistance. Existing high …
Seismic performance of precast reinforced concrete buildings with dowel pin connections
A key aspect in determining the seismic performance of industrial Precast Structures (PS)
are the connections between precast elements. The main issue is the capacity of beam …
are the connections between precast elements. The main issue is the capacity of beam …
Horizontal cladding panels: in-plane seismic performance in precast concrete buildings
The paper investigates the in-plane performance of horizontal precast reinforced concrete
cladding panels, typically adopted in one-storey precast industrial and commercial …
cladding panels, typically adopted in one-storey precast industrial and commercial …
Comparing the observed and numerically simulated seismic damage: a unified procedure for unreinforced masonry and reinforced concrete buildings
M Angiolilli, M Eteme Minkada… - Journal of Earthquake …, 2024 - Taylor & Francis
ABSTRACT A unified procedure for assessing the effectiveness of modelling strategies for
existing buildings is proposed. The procedure is applied to unreinforced masonry and cast …
existing buildings is proposed. The procedure is applied to unreinforced masonry and cast …
Cyclic response of hammer-head strap cladding-to-structure connections used in RC precast building
B Zoubek, M Fischinger, T Isaković - Engineering Structures, 2016 - Elsevier
During the recent earthquakes in the Emilia-Romagna region of Italy, the cladding-to-
structure connections which were installed in industrial precast buildings did not perform as …
structure connections which were installed in industrial precast buildings did not perform as …
Dissipating and re-centring devices for portal-frame precast structures
The seismic response of buildings not specifically designed to resist earthquake actions can
be generally improved by allowing the structure to dissipate an appropriate amount of …
be generally improved by allowing the structure to dissipate an appropriate amount of …