[HTML][HTML] Current state of the art and future directions for implantable sensors in medical technology: Clinical needs and engineering challenges

D Yogev, T Goldberg, A Arami, S Tejman-Yarden… - APL …, 2023 - pubs.aip.org
Implantable sensors have revolutionized the way we monitor biophysical and biochemical
parameters by enabling real-time closed-loop intervention or therapy. These technologies …

Point-of-care devices for the detection of biomarkers of periprosthetic joint infection: State of the art and future perspectives

V Mazzaracchio, R Vitiello, G Maccauro… - TrAC Trends in Analytical …, 2024 - Elsevier
One of the main issues in the management of periprosthetic joint infection (PJI) is related to
the correct diagnosis. Current guidelines for PJI infection are based on the 2018 …

Acidity Is an Excellent Marker of Infection in Hip and Knee Arthroplasty

T Judl, S Popelka, E Tomšík, M Hrubý, M Daniel… - Journal of Clinical …, 2024 - mdpi.com
Background: The diagnosis of joint replacement infection is a difficult clinical challenge that
often occurs when the implant cannot be salvaged. We hypothesize that the pH value of …

Real-Time pH Sensor in Bacterial Microenvironments Using Liquid Crystal Core–Shell Microspheres

Y Xie, Y Li, H Lin, X Wang, W Liao, Z Liu… - Analytical …, 2024 - ACS Publications
It is well-known that the bacterial microenvironment imposes restrictions on the growth and
behavior of bacteria. The localized monitoring of microenvironmental factors is appreciated …

Preparation of pH-sensitive surface based on mixed oxides of titanium and iridium for early detection of inflammation around the implant

J Jírů, V Hybášek, J Fojt - Materials Chemistry and Physics, 2023 - Elsevier
The surface of an implant used during operation is a preferred site for the attachment of
harmful microorganisms. These subsequently affect the surrounding tissue with their …

Functionalized orthopaedic implant as pH electrochemical sensing tool for smart diagnosis of hardware infection

L Fiore, V Mazzaracchio, C Gosti, L Duranti, R Vitiello… - Analyst, 2024 - pubs.rsc.org
In the orthopaedic surgery field, the use of medical implants to treat a patient's bone fracture
is nowadays a common practice, nevertheless, it is associated with possible cases of …

Preparation, Characterization and Electrochemical Response of Nanostructured TiAlV with Potentiostatically Deposited IrOx as a pH Sensor for Rapid Detection of …

J Jírů, V Hybášek, A Michalcová, K Korbelová… - Chemosensors, 2024 - mdpi.com
Electrochemical pH sensors have a wide range of industrial applications such as in
medicine due to their fast response and high sensitivity to pH changes. This work focuses on …

pH Sensing for Early Detection of Septic Inflammation Based on Intrinsic Titanium β-Alloy Nanotubular Oxides

J Fojt, J Šťovíček, J Jírů, V Hybášek - Metals, 2024 - mdpi.com
Orthopaedic surgeries like total hip and knee arthroplasty play a crucial role in restoring joint
function for individuals with osteoarthritis. Deep bacterial infections are one of the most …

Vývoj chytrých potenciometrických senzorů potažených vrstvami odolnými biopasivaci pro detekci raného stádia zánětlivých procesů kolem kloubních náhrad: Nové …

I Ivanko, E Tomšík, M Hrubý - Chemické listy, 2023 - chemicke-listy.cz
One of the problems occurring after the joint replacement is connected with the post-surgery
infections which are caused by bacteria that form biofilms on surfaces and are referred to as …