Fiber optic probes for biomedical optical spectroscopy
U Utzinger, RR Richards-Kortum - Journal of biomedical …, 2003 - spiedigitallibrary.org
Fiber optic probes are a key element for biomedical spectroscopic sensing. We review the
use of fiber optic probes for optical spectroscopy, focusing on applications in turbid media …
use of fiber optic probes for optical spectroscopy, focusing on applications in turbid media …
Anisotropy in the absorption and scattering spectra of chicken breast tissue
Oblique incidence reflectometry is a simple and accurate method for measuring the
absorption and the reduced-scattering coefficients of turbid media. We used this technique …
absorption and the reduced-scattering coefficients of turbid media. We used this technique …
Reflectance spectroscopy for in vivo detection of cervical precancer
YN Mirabal, SK Chang, EN Atkinson… - … of biomedical optics, 2002 - spiedigitallibrary.org
Optical technologies, in particular fluorescence spectroscopy, have shown the potential to
provide improved detection methods for cervical neoplasia that are sensitive and cost …
provide improved detection methods for cervical neoplasia that are sensitive and cost …
Light distributions from point, line and plane sources for photochemical reactions and fluorescence in turbid biological tissues
SL Jacques - Photochemistry and photobiology, 1998 - Wiley Online Library
Light distributions in biological tissues are summarized in simple expressions for sphewrical,
cylindrical and planar geometries due to point sources, line sources and planar sources …
cylindrical and planar geometries due to point sources, line sources and planar sources …
Combined reflectance and fluorescence spectroscopy for in vivo detection of cervical pre-cancer
SK Chang, YN Mirabal, EN Atkinson… - … of biomedical optics, 2005 - spiedigitallibrary.org
Optical technologies, such as reflectance and fluorescence spectroscopy, have shown the
potential to provide improved point-of-care detection methods for cervical neoplasia that are …
potential to provide improved point-of-care detection methods for cervical neoplasia that are …
Dependence of optical scattering from Intralipid in gelatin-gel based tissue-mimicking phantoms on mixing temperature and time
Intralipid is widely used as an optical scattering agent in tissue-mimicking phantoms.
Accurate control when using Intralipid is critical to match the optical diffusivity of phantoms to …
Accurate control when using Intralipid is critical to match the optical diffusivity of phantoms to …
Combined fluorescence and reflectance spectroscopy
U Utzinger, AJ Durkin, H Fuchs, AM Gillenwater… - US Patent …, 2003 - Google Patents
Methods and apparatus for performing fluorescence and spatially resolved reflectance
spectroscopy on a sample. A sample is irradiated with a fluorescence excitation fiber and …
spectroscopy on a sample. A sample is irradiated with a fluorescence excitation fiber and …
Analytical model of light reflectance for extraction of the optical properties in small volumes of turbid media
Monte Carlo simulations and experiments in tissue phantoms were used to empirically
develop an analytical model that characterizes the reflectance spectrum in a turbid medium …
develop an analytical model that characterizes the reflectance spectrum in a turbid medium …
Estimation of melanin and hemoglobin in skin tissue using multiple regression analysis aided by Monte Carlo simulation
I Nishidate, Y Aizu, H Mishina - Journal of biomedical optics, 2004 - spiedigitallibrary.org
To estimate the concentrations of melanin and blood and the oxygen saturation in human
skin tissue, we propose a method using a multiple regression analysis aided by a Monte …
skin tissue, we propose a method using a multiple regression analysis aided by a Monte …
Limitations of quantitative photoacoustic measurements of blood oxygenation in small vessels
We investigate the feasibility of obtaining accurate quantitative information, such as local
blood oxygenation level (sO 2), with a spatial resolution of about 50 µm from spectral …
blood oxygenation level (sO 2), with a spatial resolution of about 50 µm from spectral …