Directions of application of phasor measurement units for control and monitoring of modern power systems: a state-of-the-art review

A Pazderin, I Zicmane, M Senyuk, P Gubin, I Polyakov… - Energies, 2023 - mdpi.com
The development of modern power systems is directly related to changes in the traditional
principles of management, planning, and monitoring of electrical modes. The mass …

Use of clustering to reduce the number of different setting groups for adaptive coordination of overcurrent relays

M Ojaghi, V Mohammadi - IEEE Transactions on Power …, 2017 - ieeexplore.ieee.org
The facility to save multiple setting groups (SGs) within digital overcurrent relays (OCRs) is
to adapt the active setting of the relays to the current topology of the power network …

Effect of UPFC on protection of transmission lines with infeed current

M Pazoki, Z Moravej, M Khederzadeh… - … on Electrical Energy …, 2016 - Wiley Online Library
The increasing penetration of flexible AC transmission system devices and renewable
generation resources within existing conventional power system networks has necessitated …

Synchronised data‐based adaptive backup protection for series compensated line

S Sarangi, AK Pradhan - IET Generation, Transmission & …, 2014 - Wiley Online Library
Metal oxide varistor (MOV) protected series capacitor, when present in a fault loop,
modulates the impedance seen by the relay. With series capacitor placed away from the …

Adaptive setting of distance relay for MOV-protected series compensated line considering wind power

O Sivov, H Abdelsalam, E Makram - Electric Power Systems Research, 2016 - Elsevier
Abstract Series compensated lines are protected from overvoltage by metal-oxide-varistors
(MOVs) connected in parallel with the capacitor bank. The nonlinear characteristics of MOV …

[HTML][HTML] A faulty line detection technique for series compensated line using synchrophasor data

AVK Rao, KM Soni, SK Sinha, I Nasiruddin - Journal of The Institution of …, 2022 - Springer
Abstract Series compensation lines are developed to transmit huge quantum of electric
power to long distant areas. Series compensation imposes challenges to different protection …

[HTML][HTML] НАПРАВЛЕНИЯ СОВЕРШЕНСТВОВАНИЯ ФУНКЦИЙ РЕЛЕЙНОЙ ЗАЩИТЫ ЗА СЧЕТ ИСПОЛЬЗОВАНИЯ ТЕХНОЛОГИЙ СИНХРОНИЗИРОВАННЫХ …

НД Мухлынин, ПМ Ерохин… - … системы и комплексы, 2022 - cyberleninka.ru
Синхронизированные векторные измерения стоит рассматривать как набор
технологий современных «цифровых» электрических сетей, уже сегодня …

A novel overcurrent protection method based on wide area measurement in smart grid

X Jing, J Zhong, S Lin, C Zhan - 2013 IEEE Grenoble …, 2013 - ieeexplore.ieee.org
Conventional overcurrent protection settings are fixed to detect faults. Power system
operation mode varies while the settings of protection devices remain constant. As a result …

ЭЛЕКТРОТЕХНИЧЕСКИЕ СИСТЕМЫ И КОМПЛЕКСЫ

НД МУХЛЫНИН, ПМ ЕРОХИН, АВ ПАЗДЕРИН - … СИСТЕМЫ И КОМПЛЕКСЫ … - elibrary.ru
Синхронизированные векторные измерения стоит рассматривать как набор
технологий современных «цифровых» электрических сетей, уже сегодня …

Adaptive Settings of Distance Relays in the Presence of Flexible Alternating Current Transmission System (FACTS) Devices in the Nigeria Transmission Network

CE Ezendiokwelu, OA Ezechukwu… - Journal of Engineering …, 2020 - journals.unizik.edu.ng
Abstract The Flexible Alternating Current Transmission System (FACTS) devices affect the
performance of the pre-existing protective distance relay on the transmission line. These …