A systematic review of clinical applications of polymer gel dosimeters in radiotherapy

B Farhood, G Geraily, SMM Abtahi - Applied Radiation and Isotopes, 2019 - Elsevier
Radiotherapy has rapidly improved because of the use of new equipment and techniques.
Hence, the appeal for a feasible and accurate three-dimensional (3D) dosimetry system has …

[HTML][HTML] Radiation-induced non-targeted effect and carcinogenesis; implications in clinical radiotherapy

R Yahyapour, A Salajegheh, A Safari… - Journal of Biomedical …, 2018 - ncbi.nlm.nih.gov
Bystander or non-targeted effect is known to be an interesting phenomenon in radiobiology.
The genetic consequences of bystander effect on non-irradiated cells have shown that this …

[HTML][HTML] Physical, dosimetric and clinical aspects and delivery systems in neutron capture therapy

B Farhood, H Samadian, M Ghorbani… - Reports of Practical …, 2018 - Elsevier
Neutron capture therapy (NCT) is a targeted radiotherapy for cancer treatment. In this
method, neutrons with a spectra/specific energy (depending on the type of agent used for …

Calculation of Neutron Microdosimetry Spectra in Some Real Tissues Compared to Alternative Tissue Equivalent Materials

S Jahanfar, H Tavakoli-Anbaran - Arabian Journal for Science and …, 2024 - Springer
Microdosimetry studies are a description to better understand the mechanisms of biological
effects of ionizing radiation to improve cancer and minimize environmental and occupational …

Effects of Siemens TT-D carbon fiber table top on beam attenuation, and build up region of 6MV photon beam

A Sheykhoo, S Abdollahi, MHH Yazdi… - Reports of Practical …, 2017 - journals.viamedica.pl
Aim This study deals with Monte Carlo simulations of the effects which the 550 TXT carbon
fiber couch can have on the relevant parameters of a 6 [[ce: hsp sp=" 0.25"/]] MV clinical …

Tissue composition effect on dose distribution in radiotherapy with a 6 MV photon beam of a medical linac

M Ghorbani, AV Noghreiyan… - Journal of Cancer …, 2019 - journals.lww.com
Aim: The aim of this study is to evaluate soft-tissue composition effect on dose distribution for
various soft tissues in radiotherapy with a 6 MV photon beam of a medical linac …

Evaluation of the effect of soft tissue composition on the characteristics of spread-out Bragg peak in proton therapy

M Ghorbani, SB Jia, M Khosroabadi… - Journal of Cancer …, 2017 - journals.lww.com
Aim: The aim of this study is to evaluate the effect of soft tissue composition on dose
distribution and spread-out Bragg peak (SOBP) characteristics in proton therapy. Subjects …

Assessment of dose uniformity around high dose rate 192Ir and 60Co stepping sources

B Farhood, M Ghorbani - Radiological Physics and Technology, 2017 - Springer
This study aimed to evaluate dose uniformity for 192 Ir and 60 Co stepping sources. High
dose rate 192 Ir and 60 Co stepping sources were simulated by the MCNPX Monte Carlo …

Characterization of the energy and angular dependence of optically stimulated dosimeter responses in broad beam neutron radiation fields

J Conde - 2024 - krex.k-state.edu
Personal dosimeters are used in facilities where occupational radiation doses may exceed
10% of the annual radiation worker dose limit (10 CFR § 835.402, 10 CFR § 20.1502). In …

Detailed analysis of dose difference in using water as tissue-equivalent material in Cf brachytherapy

GI Vasafi, MM Firoozabadi… - Reports of Practical …, 2019 - journals.viamedica.pl
Aim The purpose of this study is to analyse how small variations in the elemental
composition of soft tissue lead to differences in dose distributions from a 252 Cf …