Dosimetry in x-ray-based breast imaging

DR Dance, I Sechopoulos - Physics in Medicine & Biology, 2016 - iopscience.iop.org
The estimation of the mean glandular dose to the breast (MGD) for x-ray based imaging
modalities forms an essential part of quality control and is needed for risk estimation and for …

The advent of anthropomorphic three-dimensional breast phantoms for X-ray imaging

K Bliznakova - Physica Medica, 2020 - Elsevier
Anthropomorphic breast phantoms are both, computational and physical, anatomically and
radiologically realistic models of the human female breast, and are considered an excellent …

Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA breast dosimetry protocols

DR Dance, KC Young… - Physics in Medicine & …, 2009 - iopscience.iop.org
Abstract The United Kingdom, European and IAEA protocols for breast dosimetry in
mammography make use of s-factors which allow for the use of different target/filter …

Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols

DR Dance, KC Young… - Physics in Medicine & …, 2010 - iopscience.iop.org
A formalism is proposed for the estimation of mean glandular dose for breast tomosynthesis,
which is a simple extension of the UK, European and IAEA protocols for dosimetry in …

Performance evaluation of digital breast tomosynthesis systems: physical methods and experimental data

NW Marshall, H Bosmans - Physics in Medicine & Biology, 2022 - iopscience.iop.org
Digital breast tomosynthesis (DBT) has become a well-established breast imaging
technique, whose performance has been investigated in many clinical studies, including a …

Virtual clinical trials in medical imaging system evaluation and optimisation

B Barufaldi, ADA Maidment, M Dustler… - Radiation Protection …, 2021 - academic.oup.com
Virtual clinical trials (VCTs) can be used to evaluate and optimise medical imaging systems.
VCTs are based on computer simulations of human anatomy, imaging modalities and image …

Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry

I Sechopoulos, K Bliznakova, X Qin, B Fei… - Medical …, 2012 - Wiley Online Library
Purpose: To compare the estimate of normalized glandular dose in mammography and
breast CT imaging obtained using the actual glandular tissue distribution in the breast to that …

Overview of patient dosimetry in diagnostic radiology in the USA for the past

W Huda, EL Nickoloff, JM Boone - Medical physics, 2008 - Wiley Online Library
This review covers the role of medical physics in addressing issues directly related to patient
dosimetry in radiography, fluoroscopy, mammography, and CT. The sections on radiography …

Breast dose in mammography is about 30% lower when realistic heterogeneous glandular distributions are considered

AM Hernandez, JA Seibert, JM Boone - Medical physics, 2015 - Wiley Online Library
Purpose: Current dosimetry methods in mammography assume that the breast is comprised
of a homogeneous mixture of glandular and adipose tissues. Three‐dimensional (3D) …

Average glandular dose in digital mammography and digital breast tomosynthesis: comparison of phantom and patient data

RW Bouwman, RE Van Engen, KC Young… - Physics in Medicine …, 2015 - iopscience.iop.org
For the evaluation of the average glandular dose (AGD) in digital mammography (DM) and
digital breast tomosynthesis (DBT) phantoms simulating standard model breasts are used …