EIT reconstruction algorithms: pitfalls, challenges and recent developments
WRB Lionheart - Physiological measurement, 2004 - iopscience.iop.org
We review developments, issues and challenges in electrical impedance tomography (EIT)
for the 4th Conference on Biomedical Applications of Electrical Impedance Tomography …
for the 4th Conference on Biomedical Applications of Electrical Impedance Tomography …
Uses and abuses of EIDORS: an extensible software base for EIT
A Adler, WRB Lionheart - Physiological measurement, 2006 - iopscience.iop.org
EIDORS is an open source software suite for image reconstruction in electrical impedance
tomography and diffuse optical tomography, designed to facilitate collaboration, testing and …
tomography and diffuse optical tomography, designed to facilitate collaboration, testing and …
Imbalances in regional lung ventilation: a validation study on electrical impedance tomography
JA Victorino, JB Borges, VN Okamoto… - American journal of …, 2004 - atsjournals.org
Imbalances in regional lung ventilation, with gravity-dependent collapse and overdistention
of nondependent zones, are likely associated to ventilator-induced lung injury. Electric …
of nondependent zones, are likely associated to ventilator-induced lung injury. Electric …
A Matlab toolkit for three-dimensional electrical impedance tomography: a contribution to the Electrical Impedance and Diffuse Optical Reconstruction Software project
N Polydorides, WRB Lionheart - Measurement science and …, 2002 - iopscience.iop.org
The objective of the Electrical Impedance and Diffuse Optical Reconstruction Software
project is to develop freely available software that can be used to reconstruct electrical or …
project is to develop freely available software that can be used to reconstruct electrical or …
Electrick: Low-cost touch sensing using electric field tomography
Current touch input technologies are best suited for small and flat applications, such as
smartphones, tablets and kiosks. In general, they are too expensive to scale to large …
smartphones, tablets and kiosks. In general, they are too expensive to scale to large …
Advancing hand gesture recognition with high resolution electrical impedance tomography
Electrical Impedance Tomography (EIT) was recently employed in the HCI domain to detect
hand gestures using an instrumented smartwatch. This prior work demonstrated great …
hand gestures using an instrumented smartwatch. This prior work demonstrated great …
Electrical resistance tomography imaging of concrete
K Karhunen, A Seppänen, A Lehikoinen… - Cement and concrete …, 2010 - Elsevier
We apply Electrical Resistance Tomography (ERT) for three dimensional imaging of
concrete. In ERT, alternating currents are injected into the target using an array of electrodes …
concrete. In ERT, alternating currents are injected into the target using an array of electrodes …
Soft tactile skin using an embedded ionic liquid and tomographic imaging
Whole-body-contact sensing will be crucial in the quest to make robots capable of safe
interaction with humans. This paper describes a novel design and a fabrication method of …
interaction with humans. This paper describes a novel design and a fabrication method of …
Electrical resistance tomography to monitor unsaturated moisture flow in cementitious materials
Traditionally the electrically-based assessment of the moisture flow in cement-based
materials relies on two-or four-point measurements. In this paper, imaging of moisture …
materials relies on two-or four-point measurements. In this paper, imaging of moisture …
A new sensing skin for qualitative damage detection in concrete elements: Rapid difference imaging with electrical resistance tomography
M Hallaji, M Pour-Ghaz - NDT & E International, 2014 - Elsevier
In this paper we investigate whether a thin layer of electrically conductive materials that is
painted to the surface of concrete elements can be used as sensing skin to detect and locate …
painted to the surface of concrete elements can be used as sensing skin to detect and locate …