High-speed OCT light sources and systems

T Klein, R Huber - Biomedical optics express, 2017 - opg.optica.org
Imaging speed is one of the most important parameters that define the performance of
optical coherence tomography (OCT) systems. During the last two decades, OCT speed has …

Probing dynamic processes in the eye at multiple spatial and temporal scales with multimodal full field OCT

J Scholler, V Mazlin, O Thouvenin, K Groux… - Biomedical optics …, 2019 - opg.optica.org
We describe recent technological progress in multimodal en face full-field optical coherence
tomography that has allowed detection of slow and fast dynamic processes in the eye. We …

Adolf Friedrich Fercher: a pioneer of biomedical optics

CK Hitzenberger - Journal of Biomedical Optics, 2017 - spiedigitallibrary.org
Adolf Friedrich Fercher, an outstanding pioneer of biomedical optics, passed away earlier
this year. He was a brilliant and visionary researcher who pioneered various fields of …

Multi-directional optical coherence tomography for retinal imaging

A Wartak, M Augustin, R Haindl, F Beer… - Biomedical optics …, 2017 - opg.optica.org
We introduce multi-directional optical coherence tomography (OCT), a technique for
investigation of the scattering properties of directionally reflective tissue samples. By …

Design considerations for murine retinal imaging using scattering angle resolved optical coherence tomography

MR Gardner, N Katta, AS Rahman, HG Rylander III… - Applied Sciences, 2018 - mdpi.com
Featured Application Scattering angle resolved optical coherence tomography offers a new
contrast mechanism for murine retinal imaging. Abstract Optical coherence tomography …

Repeatability and reproducibility of total retinal blood flow measurements using bi-directional Doppler OCT

S Szegedi, N Hommer, M Kallab… - … Vision Science & …, 2020 - tvst.arvojournals.org
Purpose: To investigate the repeatability and reproducibility of total retinal blood flow
measurements using a custom-built dual-beam bidirectional Doppler optical coherence …

Precision analysis and optimization in phase decorrelation OCT velocimetry

MGO Gräfe, M Gondre, JF de Boer - Biomedical Optics Express, 2019 - opg.optica.org
Quantitative flow velocimetry in Optical Coherence Tomography is used to determine both
the axial and lateral flow component at the level of individual voxels. The lateral flow is …

[HTML][HTML] Characterizing Normal and Tumour Blood Microcirculatory Systems Using Optical Coherence Tomography

HA Contreras-Sánchez, WJ Zabel, C Flueraru, L Lilge… - Photonics, 2024 - mdpi.com
Blood vessels transport blood and deliver essential molecules to cells. In cancer, the tumour
vasculature evolves very differently from healthy tissue, not only in morphology but also in …

Investigating spontaneous retinal venous pulsation using Doppler optical coherence tomography

A Wartak, F Beer, S Desissaire, B Baumann… - Scientific reports, 2019 - nature.com
We demonstrate the advantages of optical coherence tomography (OCT) imaging for
investigation of spontaneous retinal venous pulsation (SRVP). The pulsatile changes in …

Ocular fundus pulsations within the posterior rat eye: Chorioscleral motion and response to elevated intraocular pressure

M Augustin, S Fialová, C Fischak, L Schmetterer… - Scientific Reports, 2017 - nature.com
A multi-functional optical coherence tomography (OCT) approach is presented to determine
ocular fundus pulsations as an axial displacement between the retina and the chorioscleral …