Development of a new microdosimetric biological weighting function for the RBE10 assessment in case of the V79 cell line exposed to ions from 1H to 238U

A Parisi, T Sato, Y Matsuya, Y Kase… - Physics in Medicine …, 2020 - iopscience.iop.org
An improved biological weighting function (IBWF) is proposed to phenomenologically relate
microdosimetric lineal energy probability density distributions with the relative biological …

ICRU Report 98, Stochastic Nature of Radiation Interactions: Microdosimetry

LA Braby, V Conte, M Dingfelder… - Journal of the …, 2023 - journals.sagepub.com
ICRU Report 98, Stochastic Nature of Radiation Interactions: Microdosimetry - LA Braby, V.
Conte, M. Dingfelder, DT Goodhead, LS Pinsky, AB Rosenfeld, T. Sato, AJ Waker, S. Guatelli …

[图书][B] Radiation sensors with 3D electrodes

C Da Vià, GF Dalla Betta, S Parker - 2019 - taylorfrancis.com
Written by the leading names in this field, this book introduces the technical properties,
design and fabrication details, measurement results, and applications of three-dimensional …

Fabrication and first characterization of silicon-based full 3-D microdosimeters

A Kok, M Povoli, A Summanwar, LT Tran… - … on Nuclear Science, 2020 - ieeexplore.ieee.org
Microdosimetry provides measurements of stochastic lineal energy deposition in a
micrometric sensitive volume (SV) that are comparable to human cell dimensions, typically …

Diamond based integrated detection system for dosimetric and microdosimetric characterization of radiotherapy ion beams

C Verona, S Barna, D Georg, Y Hamad… - Medical …, 2024 - Wiley Online Library
Background Ion beam therapy allows for a substantial sparing of normal tissues and higher
biological efficacy. Synthetic single crystal diamond is a very good material to produce high …

Estimating the biological effects of helium, carbon, oxygen, and neon ion beams using 3D silicon microdosimeters

SH Lee, K Mizushima, R Kohno, Y Iwata… - Physics in Medicine …, 2021 - iopscience.iop.org
In this study, the survival fraction (SF) and relative biological effectiveness (RBE) of
pancreatic cancer cells exposed to spread-out Bragg peak helium, carbon, oxygen, and …

Validation of Geant4 for silicon microdosimetry in heavy ion therapy

D Bolst, S Guatelli, LT Tran, L Chartier… - Physics in Medicine …, 2020 - iopscience.iop.org
Microdosimetry is a particularly powerful method to estimate the relative biological
effectiveness (RBE) of any mixed radiation field. This is particularly convenient for …

The European Radiation Dosimetry Group—a 40 year success story

W Rühm, P Pihet, H Schuhmacher - Radiation Protection …, 2023 - academic.oup.com
Abstract The European Radiation Dosimetry Group (EURADOS) was founded in 1982.
Since then, the group has continuously developed and is currently a network of 80 …

Microdosimetric spectra measurements on a clinical carbon beam at nominal therapeutic fluence rate with silicon cylindrical microdosimeters

J Prieto-Pena, F Gómez, C Fleta… - … on Nuclear Science, 2019 - ieeexplore.ieee.org
The use of protons and heavy ions for the treatment of tumors is increasing since it provides
a better relative biological effectiveness (RBE) than traditional radiotherapy. Accurate …

Modelling the biological beamline at HIMAC using Geant4

D Bolst, LT Tran, S Guatelli, N Matsufuji… - Journal of Physics …, 2019 - iopscience.iop.org
A Geant4 simulation modelling the passive Biological beamline at the Heavy Ion Medical
Accelerator Chiba (HIMAC) is described and validated against experimental measurements …