Nano-scale modification of titanium implant surfaces to enhance osseointegration
The main aim of this review study was to report the state of art on the nano-scale
technological advancements of titanium implant surfaces to enhance the osseointegration …
technological advancements of titanium implant surfaces to enhance the osseointegration …
Osseointegration: hierarchical designing encompassing the macrometer, micrometer, and nanometer length scales
Objective Osseointegration has been a proven concept in implant dentistry and orthopedics
for decades. Substantial efforts for engineering implants for reduced treatment time frames …
for decades. Substantial efforts for engineering implants for reduced treatment time frames …
A brief review on the evolution of metallic dental implants: history, design, and application
In recent years, significant advances in the field of medical materials have begun to emerge,
especially in nanotechnology. The modern area of nanostructured implants possesses wide …
especially in nanotechnology. The modern area of nanostructured implants possesses wide …
Osseointegration of metallic devices: current trends based on implant hardware design
Osseointegration of metallic devices has been one of the most successful treatments in
rehabilitative dentistry and medicine over the past five decades. While highly successful, the …
rehabilitative dentistry and medicine over the past five decades. While highly successful, the …
Argon‐based atmospheric pressure plasma enhances early bone response to rough titanium surfaces
This study investigated the effect of an Argon‐based atmospheric pressure plasma (APP)
surface treatment operated chairside at atmospheric pressure conditions applied …
surface treatment operated chairside at atmospheric pressure conditions applied …
Quantitative analysis of metallic artifacts caused by dental metals: comparison of cone-beam and multi-detector row CT scanners
J Chindasombatjaroen, N Kakimoto, S Murakami… - Oral Radiology, 2011 - Springer
Objectives To quantitatively compare the streak artifacts produced by dental metals in a
cone-beam computed tomography (CBCT) device and a multi-detector row computed …
cone-beam computed tomography (CBCT) device and a multi-detector row computed …
Quality of reporting of experimental research in implant dentistry. Critical aspects in design, outcome assessment and model validation
F Vignoletti, I Abrahamsson - Journal of Clinical Periodontology, 2012 - Wiley Online Library
Objective The aim was to assess the quality of reporting of experimental research in implant
dentistry by a critical evaluation of study design, outcome assessments and model …
dentistry by a critical evaluation of study design, outcome assessments and model …
Demonstration of a SiC protective coating for titanium implants
To mitigate the corrosion of titanium implants and improve implant longevity, we investigated
the capability to coat titanium implants with SiC and determined if the coating could remain …
the capability to coat titanium implants with SiC and determined if the coating could remain …
The effect of different implant macrogeometries and surface treatment in early biomechanical fixation: an experimental study in dogs
Implant surface characterization and biomechanical testing were made to evaluate the effect
of different surface treatments along with different implant bulk configurations expressed as …
of different surface treatments along with different implant bulk configurations expressed as …
Biomechanical evaluation of undersized drilling on implant biomechanical stability at early implantation times
PURPOSE: The present study evaluated the effect of different drilling dimensions
(undersized, regular, and oversized) in the insertion and removal torques of dental implants …
(undersized, regular, and oversized) in the insertion and removal torques of dental implants …