Phase Aberration Correction for in vivo Ultrasound Localization Microscopy Using a Spatiotemporal Complex-Valued Neural Network
Ultrasound Localization Microscopy (ULM) can map microvessels at a resolution of a few
micrometers (). Transcranial ULM remains challenging in presence of aberrations caused by …
micrometers (). Transcranial ULM remains challenging in presence of aberrations caused by …
Frame rate effects and their compensation on super-resolution microvessel imaging using ultrasound localization microscopy
X Guo, D Ta, K Xu - Ultrasonics, 2023 - Elsevier
Ultrasound localization microscopy (ULM) breaks the diffraction limit and allows imaging
microvasculature at micrometric resolution while preserving the penetration depth. Frame …
microvasculature at micrometric resolution while preserving the penetration depth. Frame …
Randomized channel subsampling method for efficient ultrafast ultrasound imaging
Emerging as a novel modality with high spatiotemporal sensitivity, ultrafast ultrasound
imaging has been well established and incorporated into clinical apparatus. However, such …
imaging has been well established and incorporated into clinical apparatus. However, such …
Analytic optimization-based microbubble tracking in ultrasound super-resolution microscopy
M Ashikuzzaman, B Helfield… - 2022 IEEE International …, 2022 - ieeexplore.ieee.org
Ultrasound localization microscopy (ULM) refers to a promising medical imaging modality
that systematically leverages the advantages of contrast-enhanced ultrasound (CEUS) to …
that systematically leverages the advantages of contrast-enhanced ultrasound (CEUS) to …
Characterization of direct localization algorithms for ultrasound super-resolution imaging in a multibubble environment: A numerical and experimental study
Localization plays a significant role in the production of ultrasound localization microscopy
images. For instance, detecting more microbubbles reduces the time of acquisition, while …
images. For instance, detecting more microbubbles reduces the time of acquisition, while …
An anatomically realistic simulation framework for 3D ultrasound localization microscopy
The resolution of 3D Ultrasound Localization Microscopy (ULM) is determined by acquisition
parameters such as frequency and transducer geometry but also by microbubble (MB) …
parameters such as frequency and transducer geometry but also by microbubble (MB) …
Resolution Limits and Super-Resolution Imaging
We explore the surrounding world, from the microscopic to the astronomic scale, using a
plethora of waves. Visible light allows us to describe cells in thin slices (Hooke 1665), but …
plethora of waves. Visible light allows us to describe cells in thin slices (Hooke 1665), but …
An anatomically and hemodynamically realistic simulation framework for 3d ultrasound localization microscopy
The resolution of 3D Ultrasound Localization Microscopy (ULM) is determined by acquisition
parameters such as frequency and transducer geometry but also by microbubble (MB) …
parameters such as frequency and transducer geometry but also by microbubble (MB) …
Transfert clinique de l'échographie super résolue: application dans le rein et le cerveau humain
L Denis - 2023 - theses.hal.science
La microcirculation est un réseau de vaisseaux sanguins composé d'artérioles, de veinules
et de capillaires ayant un diamètre inférieur à 100 micromètres. Elle est le principal site …
et de capillaires ayant un diamètre inférieur à 100 micromètres. Elle est le principal site …
[PDF][PDF] An Anatomically Realistic Simulation Framework for 3D Ultrasound Localization Microscopy
P DELAFONTAINE-MARTEL, F LESAGE - academia.edu
The resolution of 3D Ultrasound Localization Microscopy (ULM) is determined by acquisition
parameters such as frequency and transducer geometry but also by microbubble (MB) …
parameters such as frequency and transducer geometry but also by microbubble (MB) …