Perspectives on lung visualization: Three‐dimensional anatomical modeling of computed and micro‐computed tomographic data in comparative evolutionary …
The vertebrate respiratory system is challenging to study. The complex relationship between
the lungs and adjacent tissues, the vast structural diversity of the respiratory system both …
the lungs and adjacent tissues, the vast structural diversity of the respiratory system both …
Assessment of regional ventilation during recruitment maneuver by electrical impedance tomography in dogs
AM Ambrósio, AF Sanchez, MAA Pereira… - Frontiers in veterinary …, 2022 - frontiersin.org
Background During protective mechanical ventilation, electrical impedance tomography
(EIT) is used to monitor alveolar recruitment maneuvers as well as the distribution of …
(EIT) is used to monitor alveolar recruitment maneuvers as well as the distribution of …
Oxygen Therapy, Mechanical Ventilation, and Anesthetic Management of Patients with Respiratory Disease
FJ Teixeira‐Neto, CL Kerr - … and Analgesia: The Sixth Edition of …, 2024 - Wiley Online Library
Sedation and general anesthesia produce profound changes in respiratory function, with the
degree of change depending on drugs employed, species involved, depth of anesthesia …
degree of change depending on drugs employed, species involved, depth of anesthesia …
Retrospective study of the changes in dynamic compliance and ventilation/perfusion mismatch following salbutamol inhalation in hypoxaemic mechanically ventilated …
J Dupont, BR Dura, A Salciccia, D Serteyn… - Veterinary Anaesthesia …, 2024 - Elsevier
Objective To study the changes in dynamic compliance (C dyn), ventilation/perfusion ()
mismatch and haemodynamic variables in hypoxaemic anaesthetized horses whose PaO 2 …
mismatch and haemodynamic variables in hypoxaemic anaesthetized horses whose PaO 2 …
Effect of end-inspiratory pause duration on respiratory system compliance calculation in mechanically ventilated dogs with healthy lungs
V García-Sanz, S Canfrán, IAG de Segura… - Veterinary Anaesthesia …, 2024 - Elsevier
Objective To compare respiratory system compliance (C RS), expressed per kilogram of
bodyweight (C RS BW), calculated without end-inspiratory pause (EIP) and after three EIP …
bodyweight (C RS BW), calculated without end-inspiratory pause (EIP) and after three EIP …
[HTML][HTML] Effect of increased resistance on dynamic compliance assessed by two clinical monitors during volume-controlled ventilation: A test-lung study
D Ben-Aderet, JHN Soares, MLC Bueno - Veterinary Anaesthesia and …, 2024 - Elsevier
Objective To evaluate the effect of increased respiratory system resistance (R RS) on
dynamic compliance (C dyn) assessed by the NM3 monitor (C dyn (NM3)–Philips …
dynamic compliance (C dyn) assessed by the NM3 monitor (C dyn (NM3)–Philips …
Comparação ecográfica do grau de atelectasia pulmonar em cães ventilados mecanicamente com e sem recurso a pressão expiratória final positiva: estudo piloto
BFB Santos - 2024 - repository.utl.pt
A formação de atelectasia pulmonar durante a anestesia geral pode levar ao
desenvolvimento de hipoxemia intraoperatória. Nos últimos anos, a investigação clínica na …
desenvolvimento de hipoxemia intraoperatória. Nos últimos anos, a investigação clínica na …
Desarrollo y evaluación de mascarillas de oxigenación en 3D diseñadas para caninos en recuperación post quirúrgica
JI Córdova-Hidalgo, ME Maldonado-Cornejo… - …, 2024 - investigarmqr.com
En la medicina veterinaria, el desarrollo de mascarillas de oxigenación en 3D para caninos
en recuperación postquirúrgica representa un avance significativo, pues proporcionan un …
en recuperación postquirúrgica representa un avance significativo, pues proporcionan un …