[HTML][HTML] THE POTENTIAL OF Ti-6Al-7Nb, AND DESIGN FOR MANUFACTURING CONSIDERATIONS IN MITIGATING FAILURE OF HIP IMPLANTS IN SERVICE.
K Posiyano, RVS Prasad, TC Dzogbewu… - Biomedical Engineering …, 2024 - Elsevier
The hip prosthesis, used to repair or recreate the diseased or damaged hip joint's
articulation functionality, greatly influences the outcome of total hip arthroplasty (THA) …
articulation functionality, greatly influences the outcome of total hip arthroplasty (THA) …
Finite element analysis of elliptical shaped stem profile of hip prosthesis using dynamic loading conditions
Patient-specific dynamic loadings are seldom considered during the evaluation of hip
implants. The primary objective of this study is to check for the feasibility of the use of …
implants. The primary objective of this study is to check for the feasibility of the use of …
Understanding the role of head size and neck length in micromotion generation at the taper junction in total hip arthroplasty
Modular hip implants allow intra-operative adjustments for patient-specific customization
and targeted replacement of damaged elements without full implant extraction. However …
and targeted replacement of damaged elements without full implant extraction. However …
Computational investigation of various stem designs with different radial clearances in total hip arthroplasty
M Kalayarasan, J Reginald, J Valerian Corda… - Cogent …, 2023 - Taylor & Francis
Hip implants are available in various shapes and sizes. This study aims to select the better
hip implant stem design and the optimal material that can be used for the implant. For all the …
hip implant stem design and the optimal material that can be used for the implant. For all the …
Enhancing structural analysis efficiency: a comprehensive review and experimental validation of advanced submodeling techniques, introducing the submodeling …
Purpose The paper's goal is to examine and illustrate the useful uses of submodeling in
finite element modeling for topology optimization and stress analysis. The goal of the study …
finite element modeling for topology optimization and stress analysis. The goal of the study …
Achieving high accuracy of Co-Cr-Mo femoral head for improving tribological properties of hip joint prosthesis via a three-axial MFAF process
L Heng, G Kim, SD Mun, JH Song - Materials Today Communications, 2024 - Elsevier
Rough surface and low precision roundness of femoral head can significantly affect
tribological properties of hip joint prosthesis such as wear, von Mises stress, friction …
tribological properties of hip joint prosthesis such as wear, von Mises stress, friction …
Assessment of polyethylene wear in dual mobility implant for Asians on various head-to-liner ratios: A finite-element analysis
Based on several references, Asians carry out several daily activities that are different from
Westerners, which require a greater range of motion. Because of that, a dual mobility (DM) …
Westerners, which require a greater range of motion. Because of that, a dual mobility (DM) …
[HTML][HTML] Finite element analysis of hip fracture risk in elderly female: The effects of soft tissue shape, fall direction, and interventions
This study investigates the effects of fall configurations on hip fracture risk with a focus on
pelvic soft tissue shape. This was done by employing a whole-body finite element (FE) …
pelvic soft tissue shape. This was done by employing a whole-body finite element (FE) …
Finite element modeling of stress distribution and safety factors in a Ti-27Nb alloy hip implant under real-world physiological loading scenarios
Total hip arthroplasty (THA) is one of the most successful orthopaedic interventions globally,
with over 450,000 procedures annually in the US alone. However, issues like aseptic …
with over 450,000 procedures annually in the US alone. However, issues like aseptic …
Non-homogeneous model for studying femur bone implants with considering defects
S Mobasseri, M Janghorban - International Journal of Modelling …, 2024 - Taylor & Francis
In this article, the natural frequencies of the femur in the presence and absence of defects
have been calculated. For this purpose, two approaches to bone modeling have been …
have been calculated. For this purpose, two approaches to bone modeling have been …