Label-Free Detection of Epinephrine Using Flower-like Biomimetic CuS Antioxidant Nanozymes
A biosensor comprising crystalline CuS nanoparticles (NPs) was synthesized via a one-step
simple coprecipitation route without involvement of a surfactant. The powder X-ray diffraction …
simple coprecipitation route without involvement of a surfactant. The powder X-ray diffraction …
A cost effective strategy for dual channel optical sensing of adrenaline based on 'in situ'formation of copper nanoparticles
U Sivasankaran, KG Kumar - Spectrochimica Acta Part A: Molecular and …, 2019 - Elsevier
Assessment of adrenaline (ADR) levels in biological fluids and pharmaceutical formulations
is of prime importance due to its association with many disease conditions. Here a novel …
is of prime importance due to its association with many disease conditions. Here a novel …
Detection of adrenaline in blood plasma as biomarker for adrenal venous sampling
D Molinnus, G Hardt, P Siegert, HS Willenberg… - …, 2018 - Wiley Online Library
An amperometric bi‐enzyme biosensor based on substrate recycling principle for the
amplification of the sensor signal has been developed for the detection of adrenaline in …
amplification of the sensor signal has been developed for the detection of adrenaline in …
Towards an adrenaline biosensor based on substrate recycling amplification in combination with an enzyme logic gate
D Molinnus, M Sorich, A Bartz, P Siegert… - Sensors and Actuators B …, 2016 - Elsevier
An amperometric biosensor using a substrate recycling principle was realized for the
detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and …
detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and …
[PDF][PDF] A Precise Quantitative detection of Adrenaline with graphite and copper nano particle film interfaced with Arduino IDE
D Gajalakshmi - Authorea Preprints, 2023 - techrxiv.org
A Precise Quantitative detection of Adrenaline with graphite and copper nano particle film
interfaced with Arduino IDE Page 1 P osted on 5 Oct 2020 — CC-BY 4.0 — h ttps://doi.org/10.36227/techrx …
interfaced with Arduino IDE Page 1 P osted on 5 Oct 2020 — CC-BY 4.0 — h ttps://doi.org/10.36227/techrx …
[PDF][PDF] Untersuchung verschiedener Schnelltests zur Bestimmung der korrekten Lage eines Katheters bei der selektiven Nebennierenvenenblutuntersuchung
C Antoniadis - 2021 - d-nb.info
Der primäre Aldosteronismus (PA) ist mit 5-12% der häufigste Grund einer sekundären
arteriellen Hypertonie, wobei der PA im Wesentlichen auf den Boden einer idiopathischen …
arteriellen Hypertonie, wobei der PA im Wesentlichen auf den Boden einer idiopathischen …