Silicon 3D microdosimeters for advanced quality assurance in particle therapy
The Centre for Medical Radiation Physics introduced the concept of Silicon On Insulator
(SOI) microdosimeters with 3-Dimensional (3D) cylindrical sensitive volumes (SVs) …
(SOI) microdosimeters with 3-Dimensional (3D) cylindrical sensitive volumes (SVs) …
Progress in 3D silicon radiation detectors
GF Dalla Betta, M Povoli - Frontiers in Physics, 2022 - frontiersin.org
In the past few years, there has been an increasing interest toward 3D silicon radiation
detectors. Owing to their unique architecture, 3D detectors provide a remarkable radiation …
detectors. Owing to their unique architecture, 3D detectors provide a remarkable radiation …
Novel detectors for silicon based microdosimetry, their concepts and applications
AB Rosenfeld - Nuclear Instruments and Methods in Physics Research …, 2016 - Elsevier
This paper presents an overview of the development of semiconductor microdosimetry and
the most current (state-of-the-art) Silicon on Insulator (SOI) detectors for microdosimetry …
the most current (state-of-the-art) Silicon on Insulator (SOI) detectors for microdosimetry …
3D-Mesa “Bridge” Silicon Microdosimeter: Charge Collection Study and Application to RBE Studies in Radiation Therapy
LT Tran, L Chartier, DA Prokopovich… - … on Nuclear Science, 2015 - ieeexplore.ieee.org
Microdosimetry is an extremely useful technique, used for dosimetry in unknown mixed
radiation fields typical of space and aviation, as well as in hadron therapy. A new silicon …
radiation fields typical of space and aviation, as well as in hadron therapy. A new silicon …
Thin silicon microdosimeter utilizing 3-D MEMS fabrication technology: Charge collection study and its application in mixed radiation fields
LT Tran, L Chartier, DA Prokopovich… - … on Nuclear Science, 2017 - ieeexplore.ieee.org
New 10--thick silicon microdosimeters utilizing 3-D technology have been developed and
investigated in this paper. The TCAD simulations were carried out to understand the …
investigated in this paper. The TCAD simulations were carried out to understand the …
3D Silicon Microdosimetry and RBE Study Using Ion of Different Energies
This paper presents a new version of the 3D mesa Bridge microdosimeter comprised of an
array of 4248 silicon cells fabricated on 10 μm thick n-type silicon-on-insulator substrate …
array of 4248 silicon cells fabricated on 10 μm thick n-type silicon-on-insulator substrate …
3D cylindrical silicon microdosimeters: fabrication, simulation and charge collection study
C Fleta, S Esteban, M Baselga, D Quirion… - Journal of …, 2015 - iopscience.iop.org
This paper reports on the fabrication, simulation, and charge collection characteristics of a
new generation of cylindrical silicon microdosimeters fabricated on SOI wafers. The devices …
new generation of cylindrical silicon microdosimeters fabricated on SOI wafers. The devices …
In-field and out-of-file application in 12C ion therapy using fully 3D silicon microdosimeters
This paper presents recent development of Silicon on Insulator (SOI) detectors for
microdosimetry at the Centre for Medical Radiation Physics (CMRP) at the University of …
microdosimetry at the Centre for Medical Radiation Physics (CMRP) at the University of …
Silicon-based three-dimensional microstructures for radiation dosimetry in hadrontherapy
C Guardiola, D Quirion, G Pellegrini, C Fleta… - Applied Physics …, 2015 - pubs.aip.org
In this work, we propose a solid-state-detector for use in radiation microdosimetry. This
device improves the performance of existing dosimeters using customized 3D-cylindrical …
device improves the performance of existing dosimeters using customized 3D-cylindrical …
3D radiation detectors: Charge collection characterisation and applicability of technology for microdosimetry
A study of charge collection in SINTEF 3D active edge silicon detectors was carried out at
ANSTO using Ion Beam Induced Charge (IBIC) technique. An IBIC study has shown that …
ANSTO using Ion Beam Induced Charge (IBIC) technique. An IBIC study has shown that …