Seismic pounding between adjacent buildings: Identification of parameters, soil interaction issues and mitigation measures

M Miari, KK Choong, R Jankowski - Soil Dynamics and Earthquake …, 2019 - Elsevier
Structural pounding has been observed in many previous earthquakes due to insufficient
gap commonly provided between adjacent structures. The collisions usually generate large …

A review on the use of the inerter device in the structural coupling technique for adjacent building vibration control

A de Souza Pippi, SM Avila, G Doz - Structures, 2022 - Elsevier
Due to the large population density in big urban centers, building taller and closer buildings
is necessary. The high flexibility of these buildings can lead to excessive vibration problems …

Application of smart dampers for prevention of seismic pounding in isolated structures subjected to near-fault earthquakes

A Rayegani, G Nouri - Journal of Earthquake Engineering, 2022 - Taylor & Francis
This paper investigates the performance of the Magnetorheological damper as a smart
dissipating device in the isolated buildings for prevention of seismic pounding. To that end …

Connection of coupled buildings: A state-of-the-art review

R Doroudi, SHH Lavassani - Structures, 2021 - Elsevier
This paper presents a state-of-the-art review of significant studies published on coupled
buildings. The approach of connecting two adjacent buildings has been effectively applied …

Pounding of structures at proximity: A state-of-the-art review

T Brown, A Elshaer - Journal of Building Engineering, 2022 - Elsevier
Pounding of structures occurs when two or more structures are within proximity subjected to
extensive lateral loading leading to a collision of structures. The pounding effect can be …

[HTML][HTML] Retrofitting of a weaker building by coupling it to an adjacent stronger building using MR dampers

M Abdeddaim, A Ounis, MK Shrimali… - Structural Engineering …, 2017 - koreascience.kr
Among various retrofitting strategies, use of semi-active control for retrofitting a building
structure has gained momentum in recent years. One of the techniques for such retrofitting is …

A design method for viscous dampers connecting adjacent structures

E Tubaldi, L Gioiella, F Scozzese, L Ragni… - Frontiers in Built …, 2020 - frontiersin.org
This paper investigates the seismic design of fluid viscous dampers connecting adjacent
structural systems. A simplified dampers design strategy is proposed, which relies on a …

[HTML][HTML] Seismic response control of adjacent buildings using optimal backward-shared tuned mass damper inerter and optimal backward-shared tuned inerter …

S Djerouni, M Abdeddaim, A Ounis - Asian Journal of Civil Engineering, 2021 - Springer
The main goal of this study is to investigate the effectiveness of backward-shared tuned
mass damper inerter (BSTMDI) in reducing inter-storey drift as well as pounding between …

Wind and seismic response control of dynamically similar adjacent buildings connected using magneto-rheological dampers

AS Baheti, VA Matsagar - Infrastructures, 2022 - mdpi.com
Wind and/or earthquake-imposed loadings on two dynamically similar adjacent buildings
cause vigorous shaking that can be mitigated using energy dissipating devices. Here, the …

Control of adjacent buildings using shared tuned mass damper

Z Guenidi, M Abdeddaim, A Ounis, MK Shrimali… - Procedia …, 2017 - Elsevier
Seismic control of adjacent buildings has received considerable attention in recent years
because of two reasons: i) for the control of the response of the two buildings simultaneously …