[HTML][HTML] Decomposition of SF6 by a plasma focus device
FM Aghamir, AR Momen-Baghdadabad, SS Salimi… - Physics Letters A, 2023 - Elsevier
Decomposition of SF 6 by a low energy plasma focus (PF) device has been investigated.
The PF device performance in SF 6 atmosphere was weaker than other gases such as …
The PF device performance in SF 6 atmosphere was weaker than other gases such as …
Deposition of tungsten in methane atmosphere using a low energy plasma focus device
AR Momen-Baghdadabad, FM Aghamir… - Ceramics …, 2023 - Elsevier
Deposition of tungsten in methane atmosphere was performed using a low energy plasma
focus device. The resulting compounds were synthesized and investigated during the …
focus device. The resulting compounds were synthesized and investigated during the …
A study of the effects of the cathode configuration on the plasma kinetics and neutron emission of plasma-focus discharges in deuterium
M Barbaglia, R Giovachini, MM Milanese… - Plasma Physics and …, 2020 - iopscience.iop.org
The differences in performance of a 1.9 kJ plasma-focus device PACO assembled with three
different cathode configurations are experimentally qualified. In particular, the current sheath …
different cathode configurations are experimentally qualified. In particular, the current sheath …
Measuring the self-generated magnetic field and the velocity of plasma flow in a pulsed plasma accelerator
A Tazhen, MK Dosbolayev - Вестник. Серия Физическая (ВКФ), 2021 - bph.kaznu.kz
In phase of radial compression the unsteady plasma flow at the exit of a pulsed plasma
accelerators is related to the generation of fast high-energy charged particle beams, to …
accelerators is related to the generation of fast high-energy charged particle beams, to …
A neutron pinhole camera for PF-24 source: Conceptual design and optimization
A fast-neutron pinhole camera based on small-area (5mm× 5 mm) BCF-12 scintillation
detectors with nanosecond time resolution has been designed. The pinhole camera is …
detectors with nanosecond time resolution has been designed. The pinhole camera is …
Analysis of neutron emission in a dense plasma focus device
A Raeisdana, SM Sadat Kiai… - Radiation Effects and …, 2021 - Taylor & Francis
Time of flight method is used to determine the emitted pulsed neutron energy spectrum from
the D (D, n) 3He and D (T, n) 4He reactions in the IR-MPF-100 (115 kJ, 40 kV, 144 µF) …
the D (D, n) 3He and D (T, n) 4He reactions in the IR-MPF-100 (115 kJ, 40 kV, 144 µF) …
[PDF][PDF] Measuring the Energy of Neutrons and Deuterons Emitted in the Plasma Focus Device
A Raeisdana, C Rasouli, E Noori, D Rostamifard - inc.nsi.ir
Experiments have been designed and performed using the IR-MPF-100 plasma focus
device. In these experiments, the charging voltage of the capacitors is 14 kV, the pressure of …
device. In these experiments, the charging voltage of the capacitors is 14 kV, the pressure of …
Conceptual design of the tomographic system for simultaneous studying of soft and hard X-ray emission from dense magnetized plasma
J Bielecki, A Wójcik-Gargula, M Scholz - Fusion Engineering and Design, 2016 - Elsevier
The article presents a new approach for investigation of spatial distributions of soft and hard
X-rays emitted from dense magnetized plasma. The approach is based on the application of …
X-rays emitted from dense magnetized plasma. The approach is based on the application of …
[图书][B] Theoretical Study of a Spherical Plasma Focus
Y Ay - 2015 - search.proquest.com
A theoretical model is developed for two concentric electrodes spherical plasma focus
device in order to investigate the plasma sheath dynamics, radiative emission, and the ion …
device in order to investigate the plasma sheath dynamics, radiative emission, and the ion …