Modeling and stability analysis of $ LCL $-type grid-connected inverters: A comprehensive overview
Due to the advantages of superior harmonics attenuation ability and reduced size, the LCL
filter has been widely adopted to interface between the inverter and the grid for improving …
filter has been widely adopted to interface between the inverter and the grid for improving …
Passivity-based design of plug-and-play current-controlled grid-connected inverters
A Akhavan, HR Mohammadi… - … on Power Electronics, 2019 - ieeexplore.ieee.org
Stable operation of LCL filtered grid-connected inverters can be achieved using active
damping. However, the stability can be threatened by non-ideal conditions such as delay in …
damping. However, the stability can be threatened by non-ideal conditions such as delay in …
Virtual inductance for stable operation of grid-interactive voltage source inverters
A Adib, B Mirafzal - IEEE Transactions on Industrial Electronics, 2018 - ieeexplore.ieee.org
In this paper, a feedforward virtual inductance control strategy is developed for the stability of
voltage source inverters (VSIs) in weak grids. A weak grid is characterized by a low short …
voltage source inverters (VSIs) in weak grids. A weak grid is characterized by a low short …
A PLL-Less Voltage Sensorless Direct Deadbeat Control for a SiC Grid-Tied Inverter With LVRT Capability Under Wide-Range Grid Impedance
SiC grid-tied inverters can reduce interface filter size and weight to reduce cost and achieve
fast dynamics, but pose control challenges, such as stability as well as large current …
fast dynamics, but pose control challenges, such as stability as well as large current …
Passivity enhancement of voltage-controlled inverters in grid-connected microgrids considering negative aspects of control delay and grid impedance variations
With growing environmental concerns, the installation of distributed generation systems
forming microgrids in power systems has received much attention recently. This panacea …
forming microgrids in power systems has received much attention recently. This panacea …
Global stability analysis for synchronous reference frame phase-locked loops
This article analyzes the global stability of synchronous reference frame phase-locked loops
(SRF-PLLs) from a large signal viewpoint. First, a large-signal model of SRF-PLL is …
(SRF-PLLs) from a large signal viewpoint. First, a large-signal model of SRF-PLL is …
Strong Adaptability Control Based on Dual-Division-Summation Current Control for an LCL-Type Grid-Connected Inverter
J Liu, X Sun, B Ren, W Song… - IEEE Transactions on …, 2022 - ieeexplore.ieee.org
The nonignorable grid impedance is one of the characteristics of a weak grid. Meanwhile,
the filter inductance also fluctuates with temperature or aging factors. The resonant …
the filter inductance also fluctuates with temperature or aging factors. The resonant …
Robust control strategy design for single-phase grid-connected converters under system perturbations
J Xia, Y Guo, X Zhang, J Jatskevich… - IEEE Transactions on …, 2019 - ieeexplore.ieee.org
In single-phase grid-connected converters, unexpected perturbations and variations of
system parameters can deteriorate the performance of grid current and dc-link voltage …
system parameters can deteriorate the performance of grid current and dc-link voltage …
A hybrid adaptive control architecture for grid-connected inverter with optimal policy generation
A nonlinear optimization-based hybrid control architecture for grid-connected inverters is
presented in this article. The proposed control approach augments the existing inverter …
presented in this article. The proposed control approach augments the existing inverter …
直驱风电场中SVG 电压前馈阻抗重构抑制次/超同步振荡方法.
杨飞, 陈燕东, 符有泽, 伍文华… - Electric Power …, 2022 - search.ebscohost.com
直驱风电场在中低频段内呈现负阻值容性的阻抗外特性, 当接入呈感性的弱电网时会相互耦合
引起次/超同步振荡, 不利于新能源的稳定消纳与电网的安全运行. 为抑制风电场的次/超同步振荡 …
引起次/超同步振荡, 不利于新能源的稳定消纳与电网的安全运行. 为抑制风电场的次/超同步振荡 …