Sizing and allocation of distributed energy resources for loss reduction using heuristic algorithms
AP Sirat, H Mehdipourpicha… - 2020 IEEE power …, 2020 - ieeexplore.ieee.org
Loss minimization in distribution networks (DN) is of great significance since the trend to the
distributed generation (DG) requires the most efficient operating scenario possible for …
distributed generation (DG) requires the most efficient operating scenario possible for …
Transient enclosure voltage (TEV) measurement system of UHV GIS and TEV statistical characterization
R Hu, X Cui, W Zhang, P Chen, L Qi, J Li… - International …, 2012 - ieeexplore.ieee.org
Transient Enclosure Voltage (TEV) generated during Ultra High Voltage (UHV) Gas
Insulated Switchgear (GIS) switch operation is a consequence of the propagation of voltage …
Insulated Switchgear (GIS) switch operation is a consequence of the propagation of voltage …
Characteristics of very fast transient currents in ultra high-voltage power system with Hybrid reactive power compensation
H Liu, T Chen, Q Sun, M Han, Q Li, WH Siew - International Journal of …, 2018 - Elsevier
Hybrid reactive power compensation (HRPC) consists of a stepped controlled shunt reactor
(SCSR) and a series compensation (SC), which will find applications in future ultra high …
(SCSR) and a series compensation (SC), which will find applications in future ultra high …
VFTO suppression by selection of a combination of initial phase angle and contact velocity
B Lu, Y Shi, H Zhan, S Duan - IEEE Transactions on Power …, 2017 - ieeexplore.ieee.org
The magnitude of very fast transients (VFTs) generated in disconnector operation in gas-
insulated substation (GIS) is mainly determined by breakdown voltage between stationary …
insulated substation (GIS) is mainly determined by breakdown voltage between stationary …
Simulation of very fast transient overvoltage on UHV 1000kV GIS test circuit
R Hu, X Cui, W Chen, Z Sun, L Qi… - … Field Problems and …, 2012 - ieeexplore.ieee.org
Some partial IEC reference circuit models of gas-insulated switchgear (GIS) components
have been slightly modified, and make them apply to a wide frequency range which meets …
have been slightly modified, and make them apply to a wide frequency range which meets …
Analysis of Magnitude and Rate-of-rise of VFTO in 550 kV GIS using EMTP-RV
Abstract Very Fast Transients (VFT) originate mainly from disconnector switching operations
in Gas Insulated Substations (GIS). In order to determine the rate-of-rise of Very Fast …
in Gas Insulated Substations (GIS). In order to determine the rate-of-rise of Very Fast …
Study of very fast transient overvoltages and mitigation techniques of a gas insulated substation
The very fast transient overvoltages (VFTOs) generated due to switching operations of gas
insulated substations (GIS) are dangerous to the equipments connected to the substations …
insulated substations (GIS) are dangerous to the equipments connected to the substations …
[PDF][PDF] Analysis of lightning strike with corona on OHTL near the substation by EMTP
Lightning protection and insulation coordination of transmission lines and substations
require an accurate knowledge of the magnitudes and waveforms of lightning overvoltage …
require an accurate knowledge of the magnitudes and waveforms of lightning overvoltage …
Estimation and analysis of VFTO at various locations in 132kV GIS substation
S Bamne, N Kinhekar - 2018 International Conference on …, 2018 - ieeexplore.ieee.org
Gas Insulated Switchgear Substation (GIS Substation) has high reliability, easy
maintenance, less area requirement etc. Due to this, it has found wide range of application …
maintenance, less area requirement etc. Due to this, it has found wide range of application …