Risk factors associated with early complications of revision surgery for head-neck taper corrosion in metal-on-polyethylene total hip arthroplasty
YM Kwon, D Rossi, J MacAuliffe, Y Peng… - The Journal of …, 2018 - Elsevier
Background Adverse local tissue reactions (ALTRs) due to tribocorrosion of head-neck taper
junctions in contemporary metal-on-polyethylene (MoP) total hip arthroplasty (THA) are …
junctions in contemporary metal-on-polyethylene (MoP) total hip arthroplasty (THA) are …
Changes in the morphology of microgrooved stem tapers with differing assembly conditions
Background Fretting and corrosion at the head-stem taper junction has been cited as a
potential clinical concern. Material loss measurement is a vital tool for quantifying changes …
potential clinical concern. Material loss measurement is a vital tool for quantifying changes …
Comparison and appraisal of techniques for the determination of material loss from tapered orthopaedic surfaces
K Dransfield, K Addinall, P Bills - Wear, 2021 - Elsevier
This review examines the challenges associated with quantifying material loss at modular
junctions. Determination of material loss from retrieved orthopaedic surfaces is regarded as …
junctions. Determination of material loss from retrieved orthopaedic surfaces is regarded as …
Method for characterization of material loss from modular head-stem taper surfaces of hip replacement devices
Assessment of the head-stem taper junction requires the estimation of material loss from the
taper surfaces of both femoral head and stem. This paper describes a method for the …
taper surfaces of both femoral head and stem. This paper describes a method for the …
Assessing the quality of inspection for tapered aircraft fastener holes using an engineer's blue contact test
B Lawless, R Heinemann, A Liaqat - Precision Engineering, 2020 - Elsevier
Tapered interference-fit fasteners (eg Taper-lok) are commonly used by the aerospace
industry due to their high fatigue strength. The inspection relies on a 'true'geometry gauge …
industry due to their high fatigue strength. The inspection relies on a 'true'geometry gauge …
Characterization of Material Loss from Femoral Stem Taper Surfaces through Development of a Responsive Morphological Filtering Technique
K Dransfield, R Racasan… - … on Beyond the …, 2018 - asmedigitalcollection.asme.org
The presence of taper junctions in hip arthroplasty designs has been suggested to
contribute to premature clinical failure, in part due to corrosion-assisted material loss …
contribute to premature clinical failure, in part due to corrosion-assisted material loss …
Comparative study of material loss at the taper interface in retrieved metal-on-polyethylene and metal-on-metal femoral components from a single manufacturer
There have been a number of reports on the occurrence of taper corrosion and/or fretting
and some have speculated on a link to the occurrence of adverse local tissue reaction …
and some have speculated on a link to the occurrence of adverse local tissue reaction …
Focus variation measurement and advanced analysis of volumetric loss at the femoral head taper interface of retrieved modular replacement hips in replica
This paper offers a technique for non-contact assessment of material volume loss at the
femoral head taper interface of modular replacement hips with novel use of the focus …
femoral head taper interface of modular replacement hips with novel use of the focus …
[PDF][PDF] euspen's 19th International Conference & Exhibition, Bilbao, ES, June 2019
Characterisation of revised orthopaedic surfaces is recognised as an essential requirement
for understanding long-term implant performance. Pre-wear data (from which to define …
for understanding long-term implant performance. Pre-wear data (from which to define …