A review on research of fire dynamics in high-rise buildings
Since serious fire occurred frequently in recent years, fire safety of high-rise building
hasattracted extensive attention. A National Basic Research Program (973 program) of …
hasattracted extensive attention. A National Basic Research Program (973 program) of …
Natural smoke filling in atrium with liquid pool fires up to 1.6 MW
WK Chow, YZ Li, E Cui, R Huo - Building and Environment, 2001 - Elsevier
Experimental studies on natural smoke filling in an atrium induced by a liquid pool fire up to
1.6 MW were carried out. The new full-scale burning facility, the PolyU/USTC Atrium …
1.6 MW were carried out. The new full-scale burning facility, the PolyU/USTC Atrium …
An investigation on spill plume development and natural filling in large full-scale atrium under retail shop fire
This paper reports an investigation on the scenarios of the spill plume and the resultant
natural filling in a full-scale atrium mock-up due to a retail shop fire. The study includes two …
natural filling in a full-scale atrium mock-up due to a retail shop fire. The study includes two …
Studies on smoke movement in stairwell induced by an adjacent compartment fire
Experiments were conducted to investigate the smoke movement in a full-scale six-storey
stairwell induced by a fire in an adjacent compartment. The smoke flow pattern in the …
stairwell induced by a fire in an adjacent compartment. The smoke flow pattern in the …
Experimental studies on natural smoke filling in atria
WK Chow, E Cui, YZ Li, R Huo… - Journal of Fire …, 2000 - journals.sagepub.com
Experimental studies on natural smoke filling during an atrium fire were carried out in a new
full-scale burning facility: the PolyU/USTC Atrium with inner length 22.4 m, width 11.9 m and …
full-scale burning facility: the PolyU/USTC Atrium with inner length 22.4 m, width 11.9 m and …
Study on fire smoke control in super-high building atrium
X Xu, Z Wang, X Liu, C Ji, N Yu, H Zhu, J Li… - Procedia engineering, 2018 - Elsevier
In this paper, hot smoke test was carried out in the atrium of 60m high in Shanghai Tower,
the law of fire smoke movement and smoke control effect has been studied under different …
the law of fire smoke movement and smoke control effect has been studied under different …
[PDF][PDF] A preliminary discussion on engineering performance-based fire codes in the Hong Kong Special Administrative Region
WK Chow - … Journal on Engineering Performance-Based Fire …, 1999 - academia.edu
The possibility of implementing Engineering Performance-Based Fire Codes (EPBFC) in the
HKSAR is briefly discussed. Topics in the existing codes where EPBFC can be applied are …
HKSAR is briefly discussed. Topics in the existing codes where EPBFC can be applied are …
On the" Cabins" Fire Safety Design Concept in the New Hong Kong Airport Terminal Building
P Beever - Journal of fire sciences, 1998 - journals.sagepub.com
The Forum is intended to provide for dialogue and discussion among fire experts, scientists
and consultants. Contributions to The Forum will not be refereed in the conventional sense …
and consultants. Contributions to The Forum will not be refereed in the conventional sense …
Atrium smoke filling process in shopping malls of Hong Kong
WK Chow - Journal of Fire Protection Engineering, 1998 - journals.sagepub.com
The smoke filling process in the atria of shopping malls in Hong Kong is studied. The atrium
is located adjacent to a shop which is assumed to have a fire. Atria classified into seven …
is located adjacent to a shop which is assumed to have a fire. Atria classified into seven …