Non-destructive evaluation for corrosion monitoring in concrete: A review and capability of acoustic emission technique
Corrosion of reinforced concrete (RC) structures has been one of the major causes of
structural failure. Early detection of the corrosion process could help limit the location and …
structural failure. Early detection of the corrosion process could help limit the location and …
Crack monitoring and damage assessment of BFRP-jacketed concrete cylinders under compression load based on acoustic emission techniques
Fiber reinforced polymer (FRP) composites have been widely used in strengthening of
existing concrete columns. However, the concrete cracks inside the FRP-strengthened …
existing concrete columns. However, the concrete cracks inside the FRP-strengthened …
Monitoring fracture of steel corroded reinforced concrete members under flexure by acoustic emission technique
Acoustic emission (AE) technique is used for monitoring and evaluating the influence of
corrosion on the structural behaviour of steel reinforced concrete (RC) beams under three …
corrosion on the structural behaviour of steel reinforced concrete (RC) beams under three …
[PDF][PDF] Application of acoustic emission to monitoring the course of the alkali-silica reaction
G Świt, J Zapała-Sławeta - Bulletin of the Polish Academy of …, 2020 - journals.pan.pl
The study presented research on the possibility of using acoustic emission to detect and
analyze the development of the alkali-silica reaction (ASR) in cement mortars. The …
analyze the development of the alkali-silica reaction (ASR) in cement mortars. The …
Event identification in acoustic emission from wire breaks in pre-stressing/post-tensioning cables
S Mahmoudkhani, J Zhao, J Cochingco… - Engineering …, 2024 - iopscience.iop.org
Steel tendons commonly used in pre-stressed/post-tensioned concrete structural systems
can lose cross-section due to corrosion, eventually leading to acoustic emission (AE) events …
can lose cross-section due to corrosion, eventually leading to acoustic emission (AE) events …
Active and passive acoustic emission-based detection of corrosion damage in steel rods and tendons
S Mahmoudkhani - 2023 - mspace.lib.umanitoba.ca
This thesis was focused on two aims: first, using acoustic emission (AE) for corrosion
damage monitoring of steel tendons, and second, using AE for corrosion damage monitoring …
damage monitoring of steel tendons, and second, using AE for corrosion damage monitoring …
Acoustic Emission Monitoring of Pre-Stressed Concrete Beams During Accelerated Corrosion of Pre-Stressing Tendons
S MAHMOUDKHANI, J ZHAO… - …, 2023 - dpi-proceedings.com.destechpub …
Acoustic sensors attached to pre-stressed/post-tensioned bridges are promising tools for
monitoring the progression of corrosion damage in pre-stressing/post-tensioning tendons. In …
monitoring the progression of corrosion damage in pre-stressing/post-tensioning tendons. In …
Nondestructive Evaluation of Corrosion Damage in Reinforced Concrete Aged Slab Specimen
RA Abduljabbar - 2018 - scholarcommons.sc.edu
The deterioration of concrete bridge decks presents a maintenance challenge for most
transportation agencies and bridge owners. This problem increases during the freeze-thaw …
transportation agencies and bridge owners. This problem increases during the freeze-thaw …
Assessment of flexural behaviour of concrete beam with corroded steel rebar using acoustic emission technique/Ahmad Zaki
Z Ahmad - 2018 - studentsrepo.um.edu.my
Corrosion of reinforced concrete (RC) structures has been one of the major causes of
structural failure. Early detection of the corrosion could help limit the location and the extent …
structural failure. Early detection of the corrosion could help limit the location and the extent …
Assessment of Flexural Behaviour of Concrete Beam with Corroded Steel Rebar Using Acoustic Emission Technique
A Zaki - 2018 - search.proquest.com
Corrosion of reinforced concrete (RC) structures has been one of the major causes of
structural failure. Early detection of the corrosion could help limit the location and the extent …
structural failure. Early detection of the corrosion could help limit the location and the extent …