The thick and thin of the central corneal thickness in glaucoma

GW Belovay, I Goldberg - Eye, 2018 - nature.com
Central corneal thickness (CCT) is an important parameter in the assessment of any
potential glaucoma patient. While it affects prognosis in ocular hypertension, its value in …

Corneal topography for intraocular lens selection in refractive cataract surgery

S Goto, N Maeda - Ophthalmology, 2021 - Elsevier
The purpose of this review is to evaluate the usefulness of corneal topography to select
premium intraocular lenses (IOLs), including aspherical IOLs, toric IOLs, and multifocal IOLs …

Corneal-thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus

R Ambrósio Jr, RS Alonso, A Luz… - Journal of Cataract & …, 2006 - Elsevier
PURPOSE: To evaluate whether the corneal-thickness spatial profile and corneal-volume
distribution differentiate keratoconic corneas from normal corneas using new tomography …

Corneal thickness changes after corneal collagen crosslinking for keratoconus and corneal ectasia: one-year results

SA Greenstein, VP Shah, KL Fry, PS Hersh - Journal of Cataract & …, 2011 - Elsevier
PURPOSE: To determine the changes in corneal thickness over time after corneal collagen
crosslinking (CXL) for keratoconus and corneal ectasia. SETTING: Cornea and refractive …

[HTML][HTML] Age-related changes in optical and biometric characteristics of emmetropic eyes

DA Atchison, EL Markwell, S Kasthurirangan… - Journal of …, 2008 - jov.arvojournals.org
We measured optical and biometric parameters of emmetropic eyes as a function of age.
There were approximately 20 subjects each in age groups 18–29, 30–39, 40–49, 50–59 …

Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements

H Shankar, D Taranath, CT Santhirathelagan… - Journal of Cataract & …, 2008 - Elsevier
PURPOSE: To comprehensively assess the reliability of automated Pentacam (Oculus, Inc.)
measurements. SETTING: Flinders Eye Centre, Flinders Medical Centre, Bedford Park …

Telemedicine for glaucoma: guidelines and recommendations

K Gan, Y Liu, B Stagg, S Rathi… - Telemedicine and e …, 2020 - liebertpub.com
Background: Glaucoma is the leading cause of irreversible blindness worldwide. Access to
glaucoma specialists is challenging and likely to become more difficult as the population …

Accuracy of corneal astigmatism estimation by neglecting the posterior corneal surface measurement

JD Ho, CY Tsai, SW Liou - American journal of ophthalmology, 2009 - Elsevier
PURPOSE: To evaluate the accuracy of corneal astigmatism estimation by neglecting the
posterior corneal surface measurement. DESIGN: Prospective, observational study …

Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus …

CMP Ponce, KM Rocha, SD Smith… - Journal of Cataract & …, 2009 - journals.lww.com
PURPOSE: To compare central (CCT) and peripheral corneal thickness (PCT) using
Scheimpflug imaging (Pentacam), high-speed optical coherence tomography (Visante OCT) …

Diurnal variation of corneal shape and thickness

SA Read, MJ Collins - Optometry and Vision Science, 2009 - journals.lww.com
Purpose. To investigate associations between the diurnal variation in a range of corneal
parameters, including anterior and posterior corneal topography, and regional corneal …