Promising functional graded materials for compact gaseous insulated switchgears/pipelines
J Li, H Liang, Y Chen, B Du - High Voltage, 2020 - Wiley Online Library
The electric field distributions along gas‐solid interfaces determine the reliability, lifetimes
and sizes of gaseous insulated switchgears/pipelines (GIS/GIL), which also affect the …
and sizes of gaseous insulated switchgears/pipelines (GIS/GIL), which also affect the …
Gas convection affecting surface charge and electric field distribution around tri-post insulators in±800 kV GIL
BX Du, JN Dong, J Li, HC Liang… - IEEE Transactions on …, 2021 - ieeexplore.ieee.org
A multi-physics simulation model of the tri-post insulator in±800 kV GIL laid horizontally is
established to study the effects of gas convection on surface charges and electric field …
established to study the effects of gas convection on surface charges and electric field …
Thermal Transport Properties of Diamond Phonons by Electric Field
Y Zhao, F Yan, X Liu, H Ma, Z Zhang, A Jiao - Nanomaterials, 2022 - mdpi.com
For the preparation of diamond heat sinks with ultra-high thermal conductivity by Chemical
Vapor Deposition (CVD) technology, the influence of diamond growth direction and electric …
Vapor Deposition (CVD) technology, the influence of diamond growth direction and electric …
Study of electric field stress on the surface contour and at the triple junction in three phase GIS with FGM spacer under the depression defect
J Pakalapati, VNK Gundavarapu… - International Journal of …, 2020 - degruyter.com
Now days, the establishment of spacers is in wide usage in three-phase Gas Insulated
Busduct (GIB) for providing mechanical support and better insulation to the conductors. The …
Busduct (GIB) for providing mechanical support and better insulation to the conductors. The …
Topology optimization and 3D printing: toward a functionally graded solid insulator
M Kurimoto - 2020 International Symposium on Electrical …, 2020 - ieeexplore.ieee.org
Topology optimization and three-dimensional (3D) printing have recently attracted attention
as potential technologies for ensuring the application of a functionally graded material to …
as potential technologies for ensuring the application of a functionally graded material to …
Numerical Simulation Research on Partial Discharge of Particle Defects at Epoxy Interface Excited by High-Frequency Sinusoidal Voltage
C Chen, J Wang, J Wang, Z Li, R Guo, H Jin, B Li - Polymers, 2023 - mdpi.com
In order to improve the effectiveness of partial discharge detection in attached metal particle
insulators, this paper proposes a partial discharge detection method for particle defects in …
insulators, this paper proposes a partial discharge detection method for particle defects in …
[HTML][HTML] Computation and analysis of electric field distribution under lightning impulse voltage for 1000-kV gas-insulated-switchgear spacer
W Yang, T Zhu, Y Tian, S Zhu, X Yang - Journal of Electrical Engineering & …, 2020 - Springer
The electric field distribution is critical to the insulation structure design of 1000-kV gas-
insulated-switchgear (GIS) equipment. At present, it is not difficult to obtain the electric field …
insulated-switchgear (GIS) equipment. At present, it is not difficult to obtain the electric field …
[HTML][HTML] Study of Electric Field Stress with Metallic Particle Adhering to FGM Spacer in Three Phase GIS
J Pakalapati, K Nagaraj… - Transactions on Electrical …, 2021 - Springer
Recently, spacer design is considered as an important factor for the smooth functioning of
three phase gas insulated busduct (GIB) to prevent itself from several defects like …
three phase gas insulated busduct (GIB) to prevent itself from several defects like …
Simulation of Permittivity and Conductivity Graded Materials for HVDC GIL for Different Voltage Forms
H Hensel, C Joergens, M Clemens - arXiv preprint arXiv:2308.14405, 2023 - arxiv.org
Functionally graded materials (FGM) are applied in HVDC gas insulated lines (GIL) to
control the electric field within the DC insulation system. In HVDC GIL, FGM with a spatial …
control the electric field within the DC insulation system. In HVDC GIL, FGM with a spatial …
Study of electrostatic field effect in a three-phase gas-insulated busduct with FGM spacer under the effect of protrusion
J Pakalapati, K Nagaraj… - … Waves and Applications, 2020 - Taylor & Francis
Recently, the defects in Gas-Insulated Busduct (GIB) affect the electric field distribution badly
over the spacer length and de-energies the GIB leading to huge loss economically. In this …