Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planning
The Monte Carlo (MC) method has been shown through many research studies to calculate
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient …
Monte Carlo modelling of external radiotherapy photon beams
F Verhaegen, J Seuntjens - Physics in medicine & biology, 2003 - iopscience.iop.org
An essential requirement for successful radiation therapy is that the discrepancies between
dose distributions calculated at the treatment planning stage and those delivered to the …
dose distributions calculated at the treatment planning stage and those delivered to the …
Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
D Sheikh‐Bagheri, DWO Rogers - Medical physics, 2002 - Wiley Online Library
A recent paper analyzed the sensitivity to various simulation parameters of the Monte Carlo
simulations of nine beams from three major manufacturers of commercial medical linear …
simulations of nine beams from three major manufacturers of commercial medical linear …
Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting: directional bremsstrahlung splitting
I Kawrakow, DWO Rogers, BRB Walters - Medical physics, 2004 - Wiley Online Library
The introduction into the BEAMnrc code of a new variance reduction technique, called
directional bremsstrahlung splitting (DBS), is described. DBS uses a combination of …
directional bremsstrahlung splitting (DBS), is described. DBS uses a combination of …
Efficiency improvements for ion chamber calculations in high energy photon beams
J Wulff, K Zink, I Kawrakow - Medical physics, 2008 - Wiley Online Library
This article presents the implementation of several variance reduction techniques that
dramatically improve the simulation efficiency of ion chamber dose and perturbation factor …
dramatically improve the simulation efficiency of ion chamber dose and perturbation factor …
A 3D photon superposition/convolution algorithm and its foundation on results of Monte Carlo calculations
W Ulmer, J Pyyry, W Kaissl - Physics in Medicine & Biology, 2005 - iopscience.iop.org
Based on previous publications on a triple Gaussian analytical pencil beam model and on
Monte Carlo calculations using Monte Carlo codes GEANT-Fluka, versions 95, 98, 2002 …
Monte Carlo calculations using Monte Carlo codes GEANT-Fluka, versions 95, 98, 2002 …
Calculation of for several small detectors and for two linear accelerators using Monte Carlo simulations
Purpose: The scope of this study was to determine a complete set of correction factors for
several detectors in static small photon fields for two linear accelerators (linacs) and for …
several detectors in static small photon fields for two linear accelerators (linacs) and for …
A virtual photon energy fluence model for Monte Carlo dose calculation
M Fippel, F Haryanto, O Dohm, F Nüsslin… - Medical …, 2003 - Wiley Online Library
The presented virtual energy fluence (VEF) model of the patient‐independent part of the
medical linear accelerator heads, consists of two Gaussian‐shaped photon sources and one …
medical linear accelerator heads, consists of two Gaussian‐shaped photon sources and one …
Beam modeling and beam model commissioning for Monte Carlo dose calculation‐based radiation therapy treatment planning: Report of AAPM Task Group 157
Dose calculation plays an important role in the accuracy of radiotherapy treatment planning
and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest …
and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest …
Total scatter factors of small beams: a multidetector and Monte Carlo study
P Francescon, S Cora, C Cavedon - Medical physics, 2008 - Wiley Online Library
The scope of this study was to estimate total scatter factors of the three smallest collimators
of the Cyberknife radiosurgery system (5–10 mm in diameter), combining experimental …
of the Cyberknife radiosurgery system (5–10 mm in diameter), combining experimental …