Interventional treatment of patent ductus arteriosus in 2004

JW Moore, DS Levi, SD Moore… - Catheterization and …, 2005 - Wiley Online Library
In 2004, the interventional treatment of patent ductus arteriosus (PDA) is definitive and
curative. In current practice, coils are used for smaller PDA, and devices are employed for …

Biomaterials and design in occlusion devices for cardiac defects: a review

Y Huang, JF Kong, SS Venkatraman - Acta Biomaterialia, 2014 - Elsevier
This review examines the biomaterials used in occlusion devices for cardiac defects, and
how the choice of these materials is dictated by design. Specifically, the devices used in …

Bibliometric analysis of patent ductus arteriosus treatments

WH Hsieh, WT Chiu, YS Lee, YS Ho - Scientometrics, 2004 - akjournals.com
A bibliometric analysis was performed to assess the quantitative trend of Patent Ductus
Arteriosus (PDA) treatment research, including intravenous injection of indomethacin and …

[PDF][PDF] Angiotensin-converting enzyme inhibitors in adults after the Mustard procedure

SJ Hechter, PM Fredriksen, P Liu… - American Journal of …, 2001 - academia.edu
There are no reports on the effect of treatment of angiotensin-converting enzyme (ACE)
inhibitors in patients with transposition of the great arteries after the Mustard procedure. We …

Immediate and late outcomes of transarterial coil occlusion of patent ductus arteriosus in dogs

FE Campbell, WP Thomas, SJ Miller… - Journal of veterinary …, 2006 - Wiley Online Library
Records from dogs (n= 125) that underwent attempted transarterial coil occlusion of patent
ductus arteriosus (PDA) at the University of California, Davis, between 1998 and 2003, were …

Patent ductus arteriosus closure in preterms less than 2 kg: surgery versus transcatheter

O Pamukcu, A Tuncay, N Narin, A Baykan… - International journal of …, 2018 - Elsevier
Background As new devices come into the market, percutaneous techniques improve and
interventionalists become more experienced; percutaneous closure gets more common in …

Transcatheter occlusion of the patent ductus arteriosus in infants: experimental testing of a new Amplatzer device

JL Bass, N Wilson - Catheterization and Cardiovascular …, 2014 - Wiley Online Library
Objectives: This study assessed the feasibility and efficacy of implanting a new miniaturized
nitinol device to occlude the patent ductus arteriosus (PDA) in a newborn porcine model …

Comparison of the incidence of residual shunting between two surgical techniques used for ligation of patent ductus arteriosus in the dog

BJ Stanley, V Luis‐Fuentes, PGG Darke - Veterinary Surgery, 2003 - Wiley Online Library
Objective—To compare the incidence of residual patent ductus arteriosus (PDA) flow after
ligation using 2 different dissection techniques: a standard dissection and a method …

[HTML][HTML] Significant persistent ductus arteriosus in infants less or equal to 6 kg: percutaneous closure or surgery?

S Abadir, Y Boudjemline, C Rey, J Petit… - Archives of …, 2009 - Elsevier
BACKGROUND: Percutaneous closure of large persistent ductus arteriosus using the
Amplatzer® duct occluder is an alternative to surgery. However, this device is not …

Transcatheter closure of a patent ductus arteriosus in a preterm infant with an Amplatzer Vascular Plug IV device

M Prsa, P Ewert - Catheterization and Cardiovascular …, 2011 - Wiley Online Library
Rapid advances in paediatric interventional cardiology allow transcatheter closure of patent