[HTML][HTML] Evolution in Casting Techniques: A Narrative Review of Casting Methods, Techniques, and Innovation

M Scheinberg, S Nihalani, L Mehta, A Shah - Cureus, 2024 - ncbi.nlm.nih.gov
Orthopedic casting has seen a remarkable evolution from ancient practices to cutting-edge
innovations. Beginning with ancient Egyptian methods employing bark, linen, and …

A biomechanical comparison of fiberglass casts and 3-dimensional–printed, open-latticed, ventilated casts

P Hoogervorst, R Knox, K Tanaka, ZM Working… - Hand, 2020 - journals.sagepub.com
Background: The aim of this study was to quantify the stabilizing properties of a 3-
dimensional (3D)-printed short-arm cast and compare those properties with traditional …

Early functional postoperative therapy of distal radius fracture with a dynamic orthosis: results of a prospective randomized cross-over comparative study

FM Stuby, S Döbele, SD Schäffer, S Mueller… - PLoS …, 2015 - journals.plos.org
Introduction This study was conducted according to GCP criteria as a prospective
randomized cross-over study. The primary goal of the study was to determine clinical …

[PDF][PDF] Early results of the conservative treatment of distal radius fractures-immobilization of the wrist in dorsal versus palmar flexion

M Grle, M Miljko, I Grle, F Hodžić, T Kapidžić - Med Glas (Zenica), 2017 - academia.edu
Early results of the conservative treatment of distal radius fractures-immobilization of the wrist in
dorsal versus palmar flexi Page 1 236 Early results of the conservative treatment of distal radius …

Outcome analysis of distal Radius fracture with Orthosis Versus cast immobilization after Palmar plate osteosynthesis: a randomized controlled study

T Klopfer, P Hemmann, V Rupprecht, F Stuby… - Journal of Personalized …, 2023 - mdpi.com
Although the benefits of hand orthoses were shown in previous studies, they have not been
able to establish themselves in clinical routines. With a focus on patient satisfaction, this …

[PDF][PDF] Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures

LR Han, CX Jin, J Yan, SZ Han, XB He, XF Yang - Genet Mol Res, 2015 - geneticsmr.com
This study compared the efficacy between external fixator combined with palmar T-plate
internal fixation and simple plate internal fixation for the treatment of comminuted distal …

[HTML][HTML] Robert Jones bandage versus cast in the treatment of distal radius fracture in children: A randomized controlled trial

J Doski, R Shaikhan - Chinese Journal of Traumatology, 2023 - Elsevier
Purpose The present study aimed to treat fractures of the distal end of the radius in children
with Robert Jones (RJ) bandage. The objective was to compare this treatment modality with …

热塑板材支具外固定与石膏外固定治疗Colles 骨折: 随机对照试验

孔长庚, 吴多庆, 符林雄, 黄友华, 王琮仁 - 中国组织工程研究, 2019 - cjter.com
热塑板材支具外固定与石膏外固定治疗Colles骨折:随机对照试验 Page 1 《中国组织工程研究》
Chinese Journal of Tissue Engineering Research 文章编号:2095-4344(2019)22-03469-06 …

External fixation of thermoplastic plate brace versus gypsum for treating Colles fracture: a randomized controlled trial

C Kong, D Wu, L Fu, Y Huang, C Wang - Chinese Journal of Tissue …, 2019 - cjter.com
BACKGROUND: The new medical thermoplastic plate brace has been widely used for the
external fixation of limb fractures, and has achieved some curative effects. But there is still no …

[引用][C] 桡骨远端骨折的非手术治疗进展

赵继荣, 李红专, 慕向前 - 中国中医骨伤科杂志, 2015