Research with plasma foci in countries of Asia, Africa, and Latin America
AE Dubinov, EI Fomicheva, LA Senilov - Reviews of Modern Plasma …, 2020 - Springer
This paper considers the modern level of technique, research, and application of “plasma
focus” facilities in the countries of Asia, Africa, and Latin America. A description of the …
focus” facilities in the countries of Asia, Africa, and Latin America. A description of the …
Scope of plasma focus with argon as a soft X-ray source
M Zakaullah, K Alamgir, M Shafiq… - IEEE transactions on …, 2002 - ieeexplore.ieee.org
The X-radiation emission from a low energy plasma focus with argon as a filling gas is
investigated. Specifically, the attention is paid to determine the system efficiency for argon K …
investigated. Specifically, the attention is paid to determine the system efficiency for argon K …
Low-energy plasma focus as a tailored X-ray source
Abstract A low-energy (2.3 kJ) plasma focus energized by a single 32-μF capacitor charged
at 12 kV with filling gases hydrogen, neon, and argon is investigated as an X-ray source …
at 12 kV with filling gases hydrogen, neon, and argon is investigated as an X-ray source …
Anode length optimization in a modified plasma focus device for optimal x-ray yields
NK Neog, SR Mohanty, E Hotta - Journal of applied physics, 2006 - pubs.aip.org
The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-
filling modified plasma focus device has been investigated. The time-resolved investigation …
filling modified plasma focus device has been investigated. The time-resolved investigation …
Plasma focus as a high intensity flash X-ray source for biological radiography
A study on X-ray emission from a low energy (3.3 kJ) plasma focus (PF) device operated
with hydrogen is reported. X-ray are detected by using an X-ray detector consisting of three …
with hydrogen is reported. X-ray are detected by using an X-ray detector consisting of three …
Numerical experiments in plasma focus operated in various gases
We adapted the Lee Model code as a branch version RADPF5. 15K to gases of special
interest to us, namely, nitrogen and oxygen and applied numerical experiments specifically …
interest to us, namely, nitrogen and oxygen and applied numerical experiments specifically …
Enhanced copper K-alpha radiation from a low-energy plasma focus
M Zakaullah, K Alamgir, M Shafiq, SM Hassan… - Applied Physics …, 2001 - pubs.aip.org
A low-energy (2.3 kJ) plasma focus is operated in an enhanced Cu Kα line emission mode.
The emission is dominated by the interaction of electrons in the current sheath with the …
The emission is dominated by the interaction of electrons in the current sheath with the …
Comparative studies of X-ray emission from a plasma focus with different metal inserts at the anode tip
X-rays emission from a low energy (1.4–5.3 kJ) Mather-type plasma focus device with
different (Cu, Mo, W and Pb) inserts at the anode tip is reported. The space and time …
different (Cu, Mo, W and Pb) inserts at the anode tip is reported. The space and time …
Study of lateral spread of ions emitted from 2.3 kJ plasma focus with hydrogen and nitrogen gases
The characteristics of ion beams of hydrogen and nitrogen with different filling pressures
emitted from the plasma focus device of 2.3 kJ energy are investigated. CR-39 SSNTDs are …
emitted from the plasma focus device of 2.3 kJ energy are investigated. CR-39 SSNTDs are …
Dependence of plasma focus argon soft X-ray yield on storage energy, total and pinch currents
M Akel, S Lee - Journal of fusion energy, 2012 - Springer
Numerical experiments are carried out systematically to determine the argon soft X-Ray
yield Y sxr for optimized argon plasma focus with storage energy E 0 from 1 kJ to 1 MJ. The …
yield Y sxr for optimized argon plasma focus with storage energy E 0 from 1 kJ to 1 MJ. The …