Estimation of 241Am and 239Pu activity embedded in the tissue using portable planar HPGe detector

M Murugan, S Ponraj, M Ramasamy… - Radiation Protection …, 2024 - academic.oup.com
This paper describes a procedure for the estimation of 241Am and 239Pu activity present in
the human tissue by measuring the depth of contaminant using a portable Planar High Purity …

Assessment of uncertainties in the lung activity measurement of low-energy photon emitters using Monte Carlo simulation of ICRP male thorax voxel phantom

MY Nadar, DK Akar, DD Rao… - Radiation protection …, 2015 - academic.oup.com
Assessment of intake due to long-lived actinides by inhalation pathway is carried out by lung
monitoring of the radiation workers inside totally shielded steel room using sensitive …

Monte Carlo simulation of enriched uranium in the lungs of thorax voxel phantom for assessment of enrichment and its effect on dose

MY Nadar, DK Akar, L Mishra, HK Patni… - Applied Radiation and …, 2021 - Elsevier
In-vivo lung monitoring is an important technique for the assessment of internal dose of
radiation workers handling actinides. At BARC, counting efficiencies (CEs) of detection …

Monte carlo simulation of skull and knee voxel phantoms for the assessment of skeletal burden of low-energy photon emitters

MY Nadar, DK Akar, HK Patni, IS Singh… - Radiation Protection …, 2014 - academic.oup.com
In case of internal contamination due to long-lived actinides by inhalation or injection
pathway, a major portion of activity will be deposited in the skeleton and liver over a period …

Direct Monitoring Method to Detect Internal Radioactive Contamination

MY Nadar, L Mishra, IS Singh - … on Radiation Environment, Volume 2: Dose …, 2024 - Springer
Direct monitoring technique for evaluation of internal contamination is a century old mature
method used for assessment of internal dose. It is used for estimation of organ/whole body …

Applying a low energy HPGe detector gamma ray spectrometric technique for the evaluation of Pu/Am ratio in biological samples

IS Singh, L Mishra, JR Yadav, MY Nadar… - Applied Radiation and …, 2015 - Elsevier
Abstract The estimation of Pu/241 Am ratio in the biological samples is an important input for
the assessment of internal dose received by the workers. The radiochemical separation of …

Monte Carlo in Internal Dosimetry

HK Patni, DK Akar - Handbook on Radiation Environment, Volume 2: Dose …, 2024 - Springer
In internal dosimetry, the Monte Carlo technique is used for radiation transport to compute
values of efficiency of monitoring systems and energy deposition in various organs followed …

Theme 4. Radiation Dosimetry (External, Internal and Biological)

H Yoshitomi, T Tsuji, T Fukami, S Nishino… - Radiation Protection …, 2023 - journals.lww.com
Materials and Methods: Indoor radiation monitoring was carried out in the Shahbag Thana
during September-December 2021. Twenty indoor locations were selected for monitoring …

Evaluation of uncertainties in lung measurement of actinides due to non-uniform distribution of activity in lungs

MY Nadar, DK Akar, DD Rao, MS Kulkarni… - Applied Radiation and …, 2017 - Elsevier
Various parameters can introduce uncertainties in the lung activity measurements of
actinides. In this study, uncertainties due to non-uniform distribution of activity in the lungs …

Evaluation of Uncertainties in lung measurements of actinides due to counting statistics

MY Nadar, DK Akar, IS Singh, PD Sawant… - Applied Radiation and …, 2019 - Elsevier
Counting statistics is an important parameter that can introduce uncertainties in the lung
activity measurements of actinides in radiation workers. Evaluation of uncertainties due to …