Cyber-enabled grids: Shaping future energy systems
As the penetration of distributed energy resources based on renewable sources increases,
several technical challenges are introduced into energy grids. These include real-time …
several technical challenges are introduced into energy grids. These include real-time …
Optical magnetic field sensors based on nanodielectrics: From biomedicine to IoT‐based energy internet
JW Zhang, X Meng, T Han, X Wei, L Wang… - IET …, 2023 - Wiley Online Library
Smart sensors with excellent performance are accelerating the development of biomedicine
and the Internet of Energy. Nanodielectrics exhibit unique electrical and mechanical …
and the Internet of Energy. Nanodielectrics exhibit unique electrical and mechanical …
[HTML][HTML] Single phase to ground fault location method of overhead line based on magnetic field detection and multi-criteria fusion
X Wang, H Du, Z Liang, L Guo, J Gao, M Kheshti… - International Journal of …, 2023 - Elsevier
The distribution network has many branches and complex structure, and the existing
protection is difficult to achieve accurate fault section location. Moreover, the monitoring …
protection is difficult to achieve accurate fault section location. Moreover, the monitoring …
[PDF][PDF] 基于磁场检测与多判据融合的架空线路接地故障定位方法
郭亮, 杜欢, 王晓卫, 梁振锋, 黄灿英… - 电力系统保护与 …, 2022 - epjournal.csee.org.cn
针对当前配电网故障区段定位难的问题, 提出了一种基于故障点前后磁场差异的故障定位新方法
. 首先, 分析了杆塔处x 轴与y 轴磁场的分布及其与相电流的关系, 同时考虑了三相导线排列差异 …
. 首先, 分析了杆塔处x 轴与y 轴磁场的分布及其与相电流的关系, 同时考虑了三相导线排列差异 …
Grounding fault location method of overhead line based on dual-axis magnetic field trajectory
X Wang, H Du, J Gao, X Wei, Z Liang… - … and Control of …, 2023 - ieeexplore.ieee.org
To address the challenges in fault location in distribution networks, the distribution of
magnetic field under overhead line and its relationship with three-phase currents are …
magnetic field under overhead line and its relationship with three-phase currents are …
A reliable fault detection algorithm for distribution network with DG resources
The natural disaster though may have less probability, but their impact can be extreme. For
instance, windstorms can result in not only single instantaneous impact, but on multiple …
instance, windstorms can result in not only single instantaneous impact, but on multiple …
Highly precise magnetic field measurement based RF-assisted Sagnac interferometer with tapered fiber
S Gu, D Feng, Y Tang, Z Li, X Nan… - IEEE Photonics …, 2022 - ieeexplore.ieee.org
A radio frequency (RF)-assisted Sagnac interferometer based on a dual-loop optoelectronic
oscillator (OEO) is experimentally demonstrated for high-precision magnetic field …
oscillator (OEO) is experimentally demonstrated for high-precision magnetic field …
Online Short-Circuit Fault Diagnosis in Three-Core Power Distribution Cable Based on Magnetic Pattern
The short-circuit fault in three-core power distribution cables is the leading cause of failure in
the power distribution network. It is imperative to diagnose it as soon as possible to avoid the …
the power distribution network. It is imperative to diagnose it as soon as possible to avoid the …
[PDF][PDF] Approximate magnetic flux density model of overhead power lines for conductor sag estimation
2_121_69_76-Approximate Magnetic Flux Density Model of Overhead Power Lines for
Conductor Sag Estimation Page 1 International Journal of Electrical Engineering and …
Conductor Sag Estimation Page 1 International Journal of Electrical Engineering and …
Laboratory setup for fault detection on overhead power lines based on magnetic field measurement
This paper presents a laboratory setup for testing and experimental verification of fault
detection methods based on contactless measurement of power line magnetic field. The …
detection methods based on contactless measurement of power line magnetic field. The …