Optimization of grounding resistance to minimize transient currents at 150 kV SULSELRABAR system
Interference on transmission system line Sungguminasa—Tallasa led to black out
(widespread outages) SULSELRABAR on Tuesday, January 19, 2016 at 14.13. The …
(widespread outages) SULSELRABAR on Tuesday, January 19, 2016 at 14.13. The …
Insulation Coordination System 150kV Substation and Transmission Line against Lightning Surge Interference in a Nickel Smelting Plant
Related with the increasing demand for electrical energy at nickel smelting plant, a highly
reliable electric power system is needed to be able to supply important loads such as …
reliable electric power system is needed to be able to supply important loads such as …
External Lightning Protection System at Pulp and Paper Industry in Areas with High Lightning Density
R Zoro, KE Widodo… - 2018 Conference on Power …, 2018 - ieeexplore.ieee.org
This research describes the installation of external lightning protection system using Single
Pole and Free Standing Mast (FSM) to protect the installation at Pulp and Paper Industry …
Pole and Free Standing Mast (FSM) to protect the installation at Pulp and Paper Industry …
An Investigation of Direct Grounding System Effect on Modeling of Lightning and Tower in Transmission Line
A Nugroho, O Abouzeid, A Syakur… - 2018 5th International …, 2018 - ieeexplore.ieee.org
Lightning strikes on transmission lines can cause disruption of electrical supply. A lightning
strike directly to the ground wire or the tower may result voltage rise on installed insulator at …
strike directly to the ground wire or the tower may result voltage rise on installed insulator at …
[PDF][PDF] Evaluasi Sistem Proteksi Petir Eksternal Pada Pabrik PT Pupuk Sriwijaya
DM Christian, EIMY Negara - Institut Teknologi Sepuluh …, 2017 - repository.its.ac.id
Indonesia termasuk daerah dengan hari guruh tertinggi di dunia yaitu 180–260 hari guruh
per tahun dengan kerapatan sambaran petir mencapai 30 sambaran per tahun. Akibat dari …
per tahun dengan kerapatan sambaran petir mencapai 30 sambaran per tahun. Akibat dari …
Analysis of Lightning Performance on 345 kV Transmission Lines Using Python Programming
F Murdiya, R Hariadi - International Journal of Electrical, Energy and …, 2020 - ijeepse.id
One of main causes of interruption of electrical power supply is the lightning strike on
overhead power transmission lines. The lightning performance of transmission line can be …
overhead power transmission lines. The lightning performance of transmission line can be …
Analisis Evaluasi Sistem Proteksi Petir (Lightning Performance) Pada Jaringan Transmisi 70 kV Gardu Induk Sukorejo–Gardu Induk Bangil
PF Satria, IB Sulistiawati, NP Agustini - SinarFe7, 2018 - journal.fortei7.org
Petir adalah suatu gejala alam yang sering terjadi di daerah tropis di Indonesia. Dengan
jumlah kerapatan sambaran petir yang sangat tinggi, jaringan transmisi 70 kV sangat rentan …
jumlah kerapatan sambaran petir yang sangat tinggi, jaringan transmisi 70 kV sangat rentan …
[PDF][PDF] Analisis Statistik Gangguan Akibat Sambaran Petir yang Terjadi pada Saluran Transmisi Di PLN Unit Pelaksana Transmisi (UPT) Semarang
A Mubarok, H Fitrianto, K Edwar - researchgate.net
Indonesia merupakan kawasan beriklim tropis yang mendapatkan curah hujan di sepanjang
tahun. Curah hujan yang besar juga selaras dengan peningkatan sambaran petir yang …
tahun. Curah hujan yang besar juga selaras dengan peningkatan sambaran petir yang …
PENGGUNAAN ATP DRAW 3.8 UNTUK MENENTUKAN JUMLAH GANGGUAN PADA SALURAN TRANSMISI 150 kV AKIBAT BACKFLASHOVER
Sambaran petir pada saluran transmisi dapat menyebabkan gangguan penyaluran tenaga
listrik. Sambaran petir langsung pada kawat tanah maupun menara dapat mengakibatkan …
listrik. Sambaran petir langsung pada kawat tanah maupun menara dapat mengakibatkan …
[PDF][PDF] ANALISIS EVALUASI SISTEM PROTEKSI PETIR (LIGHTNING PERFORMANCE) PADA JARINGAN TRANSMISI 70 kV GARDU INDUK SUKOREJO–GARDU …
PF Satria - core.ac.uk
Petir adalah suatu gejala alam yang sering terjadi di daerah tropis di Indonesia. Dengan
jumlah kerapatan sambaran petir yang sangat tinggi, jaringan transmisi 70 kV sangat rentan …
jumlah kerapatan sambaran petir yang sangat tinggi, jaringan transmisi 70 kV sangat rentan …