Reducing channel interaction through cochlear implant programming may improve speech perception: Current focusing and channel deactivation

JA Bierer, L Litvak - Trends in hearing, 2016 - journals.sagepub.com
Speech perception among cochlear implant (CI) listeners is highly variable. High degrees of
channel interaction are associated with poorer speech understanding. Two methods for …

Assessing the electrode-neuron interface with the electrically evoked compound action potential, electrode position, and behavioral thresholds

L DeVries, R Scheperle, JA Bierer - … of the Association for Research in …, 2016 - Springer
Variability in speech perception scores among cochlear implant listeners may largely reflect
the variable efficacy of implant electrodes to convey stimulus information to the auditory …

Polarity sensitivity in pediatric and adult cochlear implant listeners

KN Jahn, JG Arenberg - Trends in Hearing, 2019 - journals.sagepub.com
Modeling data suggest that sensitivity to the polarity of an electrical stimulus may reflect the
integrity of the peripheral processes of the spiral ganglion neurons. Specifically, better …

[HTML][HTML] Evaluating psychophysical polarity sensitivity as an indirect estimate of neural status in cochlear implant listeners

KN Jahn, JG Arenberg - Journal of the Association for Research in …, 2019 - Springer
The physiological integrity of spiral ganglion neurons is presumed to influence cochlear
implant (CI) outcomes, but it is difficult to measure neural health in CI listeners. Modeling …

[HTML][HTML] A site-selection strategy based on polarity sensitivity for cochlear implants: effects on spectro-temporal resolution and speech perception

T Goehring, A Archer-Boyd, JM Deeks… - Journal of the …, 2019 - Springer
Thresholds of asymmetric pulses presented to cochlear implant (CI) listeners depend on
polarity in a way that differs across subjects and electrodes. It has been suggested that lower …

[HTML][HTML] Polarity sensitivity of human auditory nerve fibers based on pulse shape, cochlear implant stimulation strategy and array

A Heshmat, S Sajedi, A Schrott-Fischer… - Frontiers in …, 2021 - frontiersin.org
Neural health is of great interest to determine individual degeneration patterns for improving
speech perception in cochlear implant (CI) users. Therefore, in recent years, several studies …

[HTML][HTML] A dynamically focusing cochlear implant strategy can improve vowel identification in noise

JG Arenberg, WS Parkinson, L Litvak, C Chen… - Ear and …, 2018 - journals.lww.com
Objectives: The standard, monopolar (MP) electrode configuration used in commercially
available cochlear implants (CI) creates a broad electrical field, which can lead to unwanted …

[HTML][HTML] Investigating the effect of blurring and focusing current in cochlear implant users with the Panoramic ECAP method

C Garcia, C Morse-Fortier, F Guérit, S Hislop… - Journal of the …, 2024 - Springer
Purpose For some cochlear implants (CIs), it is possible to focus electrical stimulation by
partially returning current from the active electrode to nearby, intra-cochlear electrodes …

[HTML][HTML] The estimated electrode-neuron interface in cochlear implant listeners is different for early-implanted children and late-implanted adults

M DiNino, G O'Brien, SM Bierer, KN Jahn… - Journal of the …, 2019 - Springer
Cochlear implant (CI) programming is similar for all CI users despite limited understanding
of the electrode-neuron interface (ENI). The ENI refers to the ability of each CI electrode to …

Identifying cochlear implant channels with relatively poor electrode-neuron interfaces using the electrically evoked compound action potential

KN Jahn, JG Arenberg - Ear and Hearing, 2020 - journals.lww.com
Objectives: The primary objective of this study was to quantify local (within ear) and global
(between ear) variation in the cochlear implant (CI) electrode-neuron interface (ENI) using …