Strengthening timber structural members with CFRP and GFRP: A state-of-the-art review

K Saad, A Lengyel - Polymers, 2022 - mdpi.com
The application of fibre-reinforced polymers (FRP) for strengthening timber structures has
proven its efficiency in enhancing load-bearing capacity and, in some cases, the stiffness of …

Are probabilistic methods a way to get rid of fudge factors? Part II: Application and examples

T Vallée, M Kaufmann, RD Adams, M Albiez… - International Journal of …, 2023 - Elsevier
Dimensioning adhesively bonded joints remains a challenging task. Their diversity in
geometry and material (including combinations thereof), characteristic stress peaks, scatter …

Experimental testing of full-scale glulam frames with buckling restrained braces

W Dong, M Li, CL Lee, G MacRae, A Abu - Engineering Structures, 2020 - Elsevier
This experimental study investigates cyclic performance of a timber-steel hybrid structural
system consisting of glulam frames and buckling restrained braces (BRBs). The BRBs are …

Mechanical performance of glued-in rod glulam beam to column moment connection: An experimental study

S Navaratnam, J Thamboo, T Ponnampalam… - Journal of Building …, 2022 - Elsevier
Engineered timber elements are gaining wide acceptance in construction with the increased
practice of mass timber structures. The design of moment resistance connection is a …

Hybrid connections for timber structures

KU Schober, T Tannert - European Journal of Wood and Wood Products, 2016 - Springer
The performance and efficiency of any structure depend on the connections that join their
components; as such they constitute the most critical component. This is also true for timber …

Experimental investigations of glued-in rod connections in CLT

GS Ayansola, T Tannert, T Vallee - Construction and Building Materials, 2022 - Elsevier
The widespread availability of cross-laminated timber (CLT) provides opportunities to extend
the use of wood structures beyond low-rise residential construction. Glued-in rods (GiR) are …

Influence of imperfections on the load capacity and stiffness of glued-in rod connections

N Ratsch, S Böhm, M Voß, M Kaufmann… - Construction and Building …, 2019 - Elsevier
Abstract Glued-in rods (GiR), which consist of rods glued into structural elements of wood, or
engineered wood products, share the manufacturing quality concerns associated to …

[HTML][HTML] Glued-in rods in cross laminated timber–Numerical simulations and parametric studies

B Azinović, H Danielsson, E Serrano… - Construction and building …, 2019 - Elsevier
Numerical simulations and parametric studies of glued-in rods in cross-laminated timber
have been performed. The simulations were based on 3D finite element analysis, using a …

Numerical investigations and capacity prediction of G-FRP rods glued into timber

C Grunwald, M Kaufmann, B Alter, T Vallée… - Composite …, 2018 - Elsevier
Abstract Glued-in-rods (GiR) represent a class of joints being used in timber engineering
that are mostly used to transfer axial loads in structural members with Glass Fibre …

The impact of defects on the capacity of timber joints with glued-in rods

E Gonzales, T Tannert, T Vallee - International Journal of Adhesion and …, 2016 - Elsevier
Glued-in rods are an increasingly used technical solution for numerous structural
applications in timber engineering, and demonstrate the potential of adhesively bonded …