Promises and challenges of grid forming: Transmission system operator, manufacturer and academic view points
C Cardozo, T Prevost, SH Huang, J Lu, N Modi… - Electric Power Systems …, 2024 - Elsevier
With the increasing penetration of power electronic converters in the power system induced
by the energy transition, Grid Forming (GFM) technology emerges as crucial for …
by the energy transition, Grid Forming (GFM) technology emerges as crucial for …
Technical advances and stability analysis in wind-penetrated power generation systems—A review
VV Yadav, B Saravanan - Frontiers in Energy Research, 2022 - frontiersin.org
Recently, wind power from renewable energy power generation has been extended quickly
to another level. To the grid, most renewable generators synchronize through the power …
to another level. To the grid, most renewable generators synchronize through the power …
PLL synchronization stability of grid-connected multiconverter systems
Phase-locked loop (PLL) synchronization instability of grid-connected converters under grid
faults is a serious concern, in particular for multiconverter plants/stations connected to a …
faults is a serious concern, in particular for multiconverter plants/stations connected to a …
A critical system strength evaluation of a power system with high penetration of renewable energy generations
L Yu, H Sun, S Xu, B Zhao… - CSEE Journal of Power …, 2021 - ieeexplore.ieee.org
The power system is experiencing a higher penetration of renewable energy generations
(REGs). The short circuit ratio (SCR) and the grid impedance ratio (GIR) are two indices to …
(REGs). The short circuit ratio (SCR) and the grid impedance ratio (GIR) are two indices to …
[PDF][PDF] 基于广义短路比的多馈入系统强度量化原理与方法: 回顾, 探讨与展望
周瑀涵, 辛焕海, 鞠平 - 中国电机工程学报, 2023 - epjournal.csee.org.cn
随着直流和新能源等电力电子设备的大量接入, 电力电子多馈入系统(简称多馈入系统)
成为现代电力系统的一种典型形态. 多馈入系统的安全稳定运行能力与其受扰后的电压响应性能 …
成为现代电力系统的一种典型形态. 多馈入系统的安全稳定运行能力与其受扰后的电压响应性能 …
Common-mode frequency in converter-integrated power systems: Definition, analysis, and quantitative evaluation
As synchronous generators (SGs) are extensively replaced by converter-based generators
(CBGs), modern power systems are facing complicated frequency stability problems …
(CBGs), modern power systems are facing complicated frequency stability problems …
[PDF][PDF] 多馈入直流系统电压稳定中静态负荷影响的定量分析和评估方法
王奕鑫, 唐宇, 叶琳, 周靖皓, 柳昂… - 电工技术 …, 2024 - dgjsxb.ces-transaction.com
摘要随着多回直流集中落点受端电网负荷中心, 交流电网相对变弱, 因此分析负荷对直流多馈入
系统电压稳定的影响, 对精确度量受端电网电压支撑能力至关重要. 该文首先建立了直流, 负荷 …
系统电压稳定的影响, 对精确度量受端电网电压支撑能力至关重要. 该文首先建立了直流, 负荷 …
Small-signal stability assessment of heterogeneous grid-following converter power systems based on grid strength analysis
The increasing penetration of renewable resources into the power network through grid-
following converters has increased the risks of small-signal instability resulting from the …
following converters has increased the risks of small-signal instability resulting from the …
新能源发电集群的改进等效短路比计算方法
朱凌志, 曲立楠, 刘纯, 陈宁 - 电力系统自动化, 2021 - epjournal.csee.org.cn
短路比是衡量电源接入点并网强度的重要指标, 低短路比并网的新能源电站发生振荡,
电压失稳等问题的风险较高. 文中首先针对新能源集群并网的场景, 分析了常用的加权短路比 …
电压失稳等问题的风险较高. 文中首先针对新能源集群并网的场景, 分析了常用的加权短路比 …
Steady-state impedance mapping in grids with power electronics: What is grid strength in modern power systems?
The paper analyzes grid strength and grid impedance for systems with significant
penetration of power electronics. The work shows that the traditionally employed Thévenin …
penetration of power electronics. The work shows that the traditionally employed Thévenin …