SPECT detectors: the Anger Camera and beyond
TE Peterson, LR Furenlid - Physics in Medicine & Biology, 2011 - iopscience.iop.org
The development of radiation detectors capable of delivering spatial information about
gamma-ray interactions was one of the key enabling technologies for nuclear medicine …
gamma-ray interactions was one of the key enabling technologies for nuclear medicine …
Maximum-likelihood methods for processing signals from gamma-ray detectors
In any gamma-ray detector, each event produces electrical signals on one or more circuit
elements. From these signals, we may wish to determine the presence of an interaction; …
elements. From these signals, we may wish to determine the presence of an interaction; …
Small animal PET: a review of what we have done and where we are going
RS Miyaoka, AL Lehnert - Physics in Medicine & Biology, 2020 - iopscience.iop.org
Small animal research is an essential tool in studying both pharmaceutical biodistribution
and disease progression over time. Furthermore, through the rapid development of in vivo …
and disease progression over time. Furthermore, through the rapid development of in vivo …
DigiPET: sub-millimeter spatial resolution small-animal PET imaging using thin monolithic scintillators
S España, R Marcinkowski, V Keereman… - Physics in Medicine …, 2014 - iopscience.iop.org
A new preclinical PET system based on dSiPMs, called DigiPET, is presented. The system is
based on thin monolithic scintillation crystals and exhibits superior spatial resolution at low …
based on thin monolithic scintillation crystals and exhibits superior spatial resolution at low …
[HTML][HTML] On the structure of dynamic principal component analysis used in statistical process monitoring
When principal component analysis (PCA) is used for statistical process monitoring it relies
on the assumption that data are time independent. However, industrial data will often exhibit …
on the assumption that data are time independent. However, industrial data will often exhibit …
Maximum-likelihood estimation with a contracting-grid search algorithm
JY Hesterman, L Caucci, MA Kupinski… - IEEE transactions on …, 2010 - ieeexplore.ieee.org
A fast search algorithm capable of operating in multi-dimensional spaces is introduced. As a
sample application, we demonstrate its utility in the 2D and 3D maximum-likelihood position …
sample application, we demonstrate its utility in the 2D and 3D maximum-likelihood position …
Advances in clinical molecular imaging instrumentation
BF Hutton, K Erlandsson, K Thielemans - Clinical and Translational …, 2018 - Springer
In this article, we describe recent developments in the design of both single-photon emission
computed tomography (SPECT) and positron emission tomography (PET) instrumentation …
computed tomography (SPECT) and positron emission tomography (PET) instrumentation …
Nonlinear least-squares modeling of 3D interaction position in a monolithic scintillator block
Z Li, M Wedrowski, P Bruyndonckx… - Physics in Medicine & …, 2010 - iopscience.iop.org
This paper presents a study of possible models to describe the relation between the
scintillation light point-of-origin and the measured photo detector pixel signals in monolithic …
scintillation light point-of-origin and the measured photo detector pixel signals in monolithic …
A 32 mm× 32 mm× 22 mm monolithic LYSO: Ce detector with dual-sided digital photon counter readout for ultrahigh-performance TOF-PET and TOF-PET/MRI
G Borghi, BJ Peet, V Tabacchini… - Physics in Medicine & …, 2016 - iopscience.iop.org
New applications for positron emission tomography (PET) and combined PET/magnetic
resonance imaging (MRI) are currently emerging, for example in the fields of neurological …
resonance imaging (MRI) are currently emerging, for example in the fields of neurological …
Towards monolithic scintillator based TOF-PET systems: practical methods for detector calibration and operation
G Borghi, V Tabacchini… - Physics in Medicine & …, 2016 - iopscience.iop.org
Gamma-ray detectors based on thick monolithic scintillator crystals can achieve spatial
resolutions< 2 mm full-width-at-half-maximum (FWHM) and coincidence resolving times …
resolutions< 2 mm full-width-at-half-maximum (FWHM) and coincidence resolving times …