Fifty years of Monte Carlo simulations for medical physics

DWO Rogers - Physics in Medicine & Biology, 2006 - iopscience.iop.org
Monte Carlo techniques have become ubiquitous in medical physics over the last 50 years
with a doubling of papers on the subject every 5 years between the first PMB paper in 1967 …

Monte Carlo modelling of external radiotherapy photon beams

F Verhaegen, J Seuntjens - Physics in medicine & biology, 2003 - iopscience.iop.org
An essential requirement for successful radiation therapy is that the discrepancies between
dose distributions calculated at the treatment planning stage and those delivered to the …

Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations

B Vanderstraeten, N Reynaert, L Paelinck… - Medical …, 2006 - Wiley Online Library
The accuracy of dose computation within the lungs depends strongly on the performance of
the calculation algorithm in regions of electronic disequilibrium that arise near tissue …

Beam modeling and beam model commissioning for Monte Carlo dose calculation‐based radiation therapy treatment planning: Report of AAPM Task Group 157

CMC Ma, IJ Chetty, J Deng, B Faddegon… - Medical …, 2020 - Wiley Online Library
Dose calculation plays an important role in the accuracy of radiotherapy treatment planning
and beam delivery. The Monte Carlo (MC) method is capable of achieving the highest …

Conversion of CT numbers into tissue parameters for Monte Carlo dose calculations: a multi-centre study

B Vanderstraeten, PW Chin, M Fix, A Leal… - Physics in Medicine …, 2007 - iopscience.iop.org
The conversion of computed tomography (CT) numbers into material composition and mass
density data influences the accuracy of patient dose calculations in Monte Carlo treatment …

Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millennium multileaf collimator

E Heath, J Seuntjens - Physics in Medicine & Biology, 2003 - iopscience.iop.org
A new component module (CM), designated DYNVMLC, was developed to fully model the
geometry of the Varian Millennium 120 leaf collimator using the BEAMnrc Monte Carlo code …

Report of AAPM Therapy Physics Committee Task Group 74: in‐air output ratio, for megavoltage photon beams

TC Zhu, A Ahnesjö, KL Lam, XA Li, CMC Ma… - Medical …, 2009 - Wiley Online Library
The concept of in‐air output ratio was introduced to characterize how the incident photon
fluence per monitor unit (or unit time for a Co‐60 unit) varies with collimator settings …

Monte Carlo methods for device simulations in radiation therapy

H Park, H Paganetti, J Schuemann… - Physics in Medicine & …, 2021 - iopscience.iop.org
Monte Carlo (MC) simulations play an important role in radiotherapy, especially as a method
to evaluate physical properties that are either impossible or difficult to measure. For …

Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear …

E Sterpin, M Tomsej, B De Smedt, N Reynaert… - Medical …, 2007 - Wiley Online Library
The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition
algorithm proposed by Varian for photon dose calculations. The configuration of AAA …

The influence of small field sizes, penumbra, spot size and measurement depth on perturbation factors for microionization chambers

F Crop, N Reynaert, G Pittomvils… - Physics in Medicine …, 2009 - iopscience.iop.org
The purpose of this study was the investigation of perturbation factors for microionization
chambers in small field dosimetry and the influence of penumbra for different spot sizes. To …