Tribology of total artificial joints
J Fisher, D Dowson - … , Part H: Journal of Engineering in …, 1991 - journals.sagepub.com
The tribology of total artificial replacement joints is reviewed. The majority of prostheses
currently implanted comprise a hard metallic component which articulates on ultra high …
currently implanted comprise a hard metallic component which articulates on ultra high …
The response to particulate debris
DW Howie, SD Rogers, MA McGee, MJ Pearcy… - Orthopedic Clinics of …, 1993 - Elsevier
The most common cause of failure of total hip and other arthroplasties is aseptic loosening
of the prosthesis. Substantial evidence suggests that the adverse tissue response to …
of the prosthesis. Substantial evidence suggests that the adverse tissue response to …
Tissue response in relation to type of wear particles around failed hip arthroplasties
DW Howie - The Journal of arthroplasty, 1990 - Elsevier
To establish the types of wear particles and associated tissue response around human
prostheses the periprosthetic tissues around 50 hip arthroplasties revised for aseptic …
prostheses the periprosthetic tissues around 50 hip arthroplasties revised for aseptic …
Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions
A Wang, A Essner, C Stark, JH Dumbleton - Biomaterials, 1996 - Elsevier
This paper investigates the effect of lubricant on the size and morphology of ultra-high
molecular weight polyethylene (UHMWPE) wear debris produced by a hip joint simulator …
molecular weight polyethylene (UHMWPE) wear debris produced by a hip joint simulator …
On the true wear rate of ultra high-molecular-weight polyethylene in the total hip prosthesis.
RM Rose, HJ Nusbaum, H Schneider, M Ries, I Paul… - JBJS, 1980 - journals.lww.com
Six total hip prostheses of the Charnley-Mueller design from six different manufacturers were
tested by total joint simulation for the equivalent of one year of use. Two Charnley …
tested by total joint simulation for the equivalent of one year of use. Two Charnley …
Role of cyclic plastic deformation in the wear of UHMWPE acetabular cups
A Wang, C Stark, JH Dumbleton - Journal of biomedical …, 1995 - Wiley Online Library
The mechanisms of wear in ultra‐high‐molecular‐weight polyethylene (UHMWPE)
acetabular cups were investigated on both laboratory simulator‐tested cups and a clinically …
acetabular cups were investigated on both laboratory simulator‐tested cups and a clinically …
On the pressure dependence of the wear of ultrahigh molecular weight polyethylene
RM Rose, HV Goldfarb, E Ellis, AM Crugnola - Wear, 1983 - Elsevier
The wear of polyethylene in bovine serum was evaluated as a function of load and
molecular weight. The range and distribution of contact loadings simulated those which exist …
molecular weight. The range and distribution of contact loadings simulated those which exist …
Isolation and morphological characterisation of UHMWPE wear debris generated in vitro
S Affatato, B Fernandes, A Tucci, L Esposito, A Toni - Biomaterials, 2001 - Elsevier
Wear tests are generally carried out on materials used in prosthetic hip implants, in order to
obtain a better understanding of the tribological processes involved and improve the quality …
obtain a better understanding of the tribological processes involved and improve the quality …
Exploratory investigations on the structure dependence of the wear resistance of polyethylene
RM Rose, WR Cimino, E Ellis, AN Crugnola - Wear, 1982 - Elsevier
A relatively simple hemisphere-on-flat sliding wear tester was devised for screening
samples of polyethylene prior to their trial in total joint simulators and ultimately in implanted …
samples of polyethylene prior to their trial in total joint simulators and ultimately in implanted …
Mixed oxides prosthetic ceramic ball heads. Part 1: effect of the ZrO2 fraction on the wear of ceramic on polyethylene joints
S Affatato, M Testoni, GL Cacciari, A Toni - Biomaterials, 1999 - Elsevier
Although mixed oxides ceramics have been indicated in the literature as a promising
compromise between strength and wear, to the authors' knowledge no reports are available …
compromise between strength and wear, to the authors' knowledge no reports are available …