Report of AAPM Task Group 155: megavoltage photon beam dosimetry in small fields and non‐equilibrium conditions
IJ Das, P Francescon, JM Moran, A Ahnesjö… - Medical …, 2021 - Wiley Online Library
Small‐field dosimetry used in advance treatment technologies poses challenges due to loss
of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and …
of lateral charged particle equilibrium (LCPE), occlusion of the primary photon source, and …
Multi‐institution validation of a new high spatial resolution diode array for SRS and SBRT plan pretreatment quality assurance
MS Rose, L Tirpak, K Van Casteren, J Zack… - Medical …, 2020 - Wiley Online Library
Purpose The SRS MapCHECK®, a recently developed patient‐specific quality assurance
(PSQA) tool for end‐to‐end testing of stereotactic radiosurgery (SRS) and stereotactic body …
(PSQA) tool for end‐to‐end testing of stereotactic radiosurgery (SRS) and stereotactic body …
Impact of the MLC leaf‐tip model in a commercial TPS: dose calculation limitations and IROC‐H phantom failures
Purpose Treatment planning system (TPS) dose calculation is sensitive to multileaf
collimator (MLC) modeling, especially when treating with intensity‐modulated radiation …
collimator (MLC) modeling, especially when treating with intensity‐modulated radiation …
[HTML][HTML] Plan quality comparison for cervical carcinoma treated with Halcyon and Trilogy intensity-modulated radiotherapy
C Li, J Chen, J Zhu, G Gong, C Tao, Z Li, J Lu… - Journal of …, 2019 - ncbi.nlm.nih.gov
Purpose: Varian Halcyon is a novel machine with dual-layer leaves, single flattening filter
free (FFF) energy and an enclosed bore. The purpose of this study was to compare the …
free (FFF) energy and an enclosed bore. The purpose of this study was to compare the …
Deep learning‐based detection and classification of multi‐leaf collimator modeling errors in volumetric modulated radiation therapy
S Nakamura, M Sakai, N Ishizaka… - Journal of Applied …, 2023 - Wiley Online Library
Purpose The purpose of this study was to create and evaluate deep learning‐based models
to detect and classify errors of multi‐leaf collimator (MLC) modeling parameters in volumetric …
to detect and classify errors of multi‐leaf collimator (MLC) modeling parameters in volumetric …
[HTML][HTML] Relationship between dosimetric leaf gap and dose calculation errors for high definition multi-leaf collimators in radiotherapy
J Kim, JS Han, AT Hsia, S Li, Z Xu, S Ryu - Physics and imaging in …, 2018 - Elsevier
Background and purpose Dosimetric leaf gap (DLG) is a parameter to model the round-leaf-
end effect of multi-leaf collimators (MLC) that is important for treatment planning dose …
end effect of multi-leaf collimators (MLC) that is important for treatment planning dose …
Monte Carlo-based independent dose verification of radiosurgery HyperArc plans
JF Calvo-Ortega, S Moragues-Femenía, C Laosa-Bello… - Physica Medica, 2022 - Elsevier
Purpose To investigate the feasibility of using the free PRIMO Monte Carlo software for
independent dose check of cranial SRS plans designed with the Varian HyperArc (HA) …
independent dose check of cranial SRS plans designed with the Varian HyperArc (HA) …
On the need for tuning the dosimetric leaf gap for stereotactic treatment plans in the Eclipse treatment planning system
L Vieillevigne, C Khamphan, J Saez… - Journal of applied …, 2019 - Wiley Online Library
The dosimetric leaf gap (DLG) and tongue‐and‐groove (T&G) effects are critical aspects in
the modeling of multileaf collimators (MLC) in the treatment planning system (TPS). In this …
the modeling of multileaf collimators (MLC) in the treatment planning system (TPS). In this …
A novel procedure for determining the optimal MLC configuration parameters in treatment planning systems based on measurements with a Farmer chamber
Modelling of the multi-leaf collimator (MLC) in treatment planning systems (TPS) is crucial for
the dose calculation accuracy of intensity-modulated radiation therapy plans. However, no …
the dose calculation accuracy of intensity-modulated radiation therapy plans. However, no …
Sensitivity of IROC phantom performance to radiotherapy treatment planning system beam modeling parameters based on community‐driven data
Purpose Treatment planning system (TPS) dose calculations have previously been shown to
be sensitive to modeling errors, especially when treating with complex strategies like …
be sensitive to modeling errors, especially when treating with complex strategies like …