Design and optimization of roof-top fire water tanks as compliant deep tank dampers-inerter for seismic protection of multi-storeyed buildings

A Das, T Konar - Journal of Building Engineering, 2023 - Elsevier
Water tanks are installed on the roofs of high-rise buildings for services and to fight fire
outbreaks. These tanks are often considered unsuitable for design as tuned liquid dampers …

Wind-induced vibration control of tall buildings by designing the overhead fire water tanks as compliant deep tank dampers-inerter

A Das, T Konar, A Banerjee - Structures, 2023 - Elsevier
Building codes often mandate the installation of overhead fire water tanks (OFWTs) on multi-
storeyed buildings. The present study proposes a cost-effective solution by utilizing these …

Revisiting equivalent tuned mass damper analogy for tuned liquid damper utilizing CFD-FEA framework

A Das, T Konar, D Maity, SK Bhattacharyya - Soil Dynamics and …, 2023 - Elsevier
The equivalent mechanical model (EMM) of a tuned liquid damper (TLD) is represented
through an analogous spring-mass-dashpot system that resembles a tuned mass damper …

Dynamics of a submerged compound pendulum

A Das, T Konar, A Ghosh, D Maity - International Journal of …, 2024 - World Scientific
This paper focuses on the dynamics of a submerged compound pendulum (SCP). The
considered pendulum consists of a horizontal cylindrical element at its lowermost portion …

Design of Intermediate-Depth Tuned Liquid Damper with Horizontal Baffles for Seismic Control and Carbon Footprint Reduction of Buildings

T Konar - Journal of Vibration Engineering & Technologies, 2024 - Springer
Purpose Intermediate-depth tuned liquid dampers (TLDs) are easier to install and maintain
as compared to shallow TLDs but produce less damping. The purpose of this study is to …

Performance comparison of linear and nonlinear compliant liquid dampers-inerter in controlling across-wind response of benchmark tall building

A Das, A Banerjee, DR Sahoo, V Matsagar - Journal of Building …, 2024 - Elsevier
The potential of compliant liquid dampers-inerter (CLDI) for response control of tall
buildings, capitalizing on the mass amplification property of the inerter, has been explored …

A novel tuned liquid damper for vibration control in high-frequency structures

M Domizio, D Ambrosini, A Campi - Engineering Structures, 2024 - Elsevier
This paper presents a novel device as an alternative to the classical tuned liquid damper
(TLD). Unlike conventional TLDs, the proposed device is capable of controlling the dynamic …

[引用][C] Design of an Overhead Water Tank as a Passive Tuned Damper Using an Innovative Support System Adaptive to Liquid Depth Fluctuation in the Tank

T Konar - Journal of Earthquake and Tsunami, 2024 - World Scientific
Difficulty in maintaining tuning due to water depth fluctuation makes overhead water tanks
(OWTs) ineffective as tuned liquid or mass dampers. Recently, a semi-active damper …