The future of computed tomography: personalized, functional, and precise

H Alkadhi, A Euler - Investigative radiology, 2020 - journals.lww.com
Modern medicine cannot be imagined without the diagnostic capabilities of computed
tomography (CT). Although the past decade witnessed a tremendous increase in scan …

Vendor free basics of radiation dose reduction techniques for CT

T Kubo - European Journal of Radiology, 2019 - Elsevier
Although radiation dose in computed tomography (CT) decreased and CT became safer
examinations than before, CT is the most significant source of the medical radiation …

Deep learning-based fully automated Z-axis coverage range definition from scout scans to eliminate overscanning in chest CT imaging

Y Salimi, I Shiri, A Akhavanallaf, Z Mansouri… - Insights into …, 2021 - Springer
Background Despite the prevalence of chest CT in the clinic, concerns about unoptimized
protocols delivering high radiation doses to patients still remain. This study aimed to assess …

Patient organ and effective dose estimation in CT: comparison of four software applications

C De Mattia, F Campanaro, F Rottoli… - European radiology …, 2020 - Springer
Background Radiation dose in computed tomography (CT) has become a topic of high
interest due to the increasing numbers of CT examinations performed worldwide. Hence …

Thyroid dose reduction shield with the generation of less artifacts used for fast chest CT examination

K Takegami, H Hayashi, T Maeda, C Lee… - Radiation Physics and …, 2023 - Elsevier
Fast chest CT scans with high-pitch factors are effective to reduce motion artifacts, but the
over-ranging effect may increase harmful radiation exposure to organs which are located …

Over-scanning in chest CT: comparison of practice among six hospitals and its impact on radiation dose

F Schwartz, B Stieltjes, Z Szucs-Farkas… - European journal of …, 2018 - Elsevier
Objectives Compare incidence of over-scanning in chest CT among six hospitals and impact
on effective and organ effective radiation dose. Methods Scout images of 600 chest CTs …

Convolutional neural network evaluation of over-scanning in lung computed tomography

M Colevray, VM Tatard-Leitman, S Gouttard… - Diagnostic and …, 2019 - Elsevier
Introduction The purpose of this study was to develop a convolutional neural network (CNN)
to determine the extent of over-scanning in the Z-direction associated with lung computed …

Real practice radiation dose and dosimetric impact of radiological staff training in body CT examinations

F Paolicchi, L Faggioni, L Bastiani, S Molinaro… - Insights into …, 2013 - Springer
Objectives To evaluate the radiation dose of the main body CT examinations performed
routinely in four regional diagnostic centres, the specific contribution of radiologists and …

A suitable procedure of dose reduction factor measurements of X-ray shields during computed tomography examination-The importance of considering positional …

H Hayashi, T Maeda, K Takegami, R Nishigami… - Radiation Physics and …, 2024 - Elsevier
During computed tomography (CT) examinations, radio-sensitive organs located outside the
field of view (FOV) are usually exposed to radiation caused by both direct and scattered X …

Radiation dose exposure in patients affected by lymphoma undergoing repeat CT examinations: how to manage the radiation dose variability

F Paolicchi, L Bastiani, D Guido, A Dore… - La radiologia …, 2018 - Springer
Purpose To assess the variability of radiation dose exposure in patients affected by
lymphoma undergoing repeat CT (computed tomography) examinations and to evaluate the …