IEEE 1588 for clock synchronization in industrial IoT and related applications: A review on contributing technologies, protocols and enhancement methodologies
Precise time synchronization becomes a vital constituent due to the rigorous needs of
several time-sensitive applications. The clock synchronization protocol is one of the …
several time-sensitive applications. The clock synchronization protocol is one of the …
An application of fuzzy fault tree analysis for reliability evaluation of wind energy system
In this paper, a fuzzy fault tree analysis technique for reliability evaluation of the wind energy
system is presented. The technique combines the operational failures effect and the errors in …
system is presented. The technique combines the operational failures effect and the errors in …
Design of a time synchronization system based on GPS and IEEE 1588 for transmission substations
H Guo, P Crossley - IEEE Transactions on power delivery, 2016 - ieeexplore.ieee.org
Accurate timing is often required for the intelligent electronic devices (IEDs) used in
transmission substations. A common method of achieving this is direct connection of a …
transmission substations. A common method of achieving this is direct connection of a …
A Cyber Resilient Protection Scheme for Bipolar DC Microgrids Using Symmetrical Component Decomposition
A Pandey, SR Mohanty… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
This article presents a unit protection scheme for bipolar dc microgrids, which is resilient to
cyber attacks. The proposed method uses current measurement of both ends of the …
cyber attacks. The proposed method uses current measurement of both ends of the …
An intrusion detection method for line current differential relays in medium-voltage DC microgrids
Line current differential relays (LCDRs) detect faults accurately and promptly, by comparing
all currents flowing into the line. This type of relay has been identified in the literature as a …
all currents flowing into the line. This type of relay has been identified in the literature as a …
IEEE 1588 time synchronisation performance for IEC 61850 transmission substations
M Han, H Guo, P Crossley - International Journal of Electrical Power & …, 2019 - Elsevier
Accurate timestamping with 1 µs precision is required by power system monitoring and
control equipment, including: Phase Measurement Units (PMUs) for real-time measurement …
control equipment, including: Phase Measurement Units (PMUs) for real-time measurement …
A fast protection relay for mmc-based dc grids robust to cyber-physical anomalies
Half-bridge modular multilevel converters (HBMMCs) are widely applied in modern DC
grids, where converter substations have a cyber-physical structure similar to that of a typical …
grids, where converter substations have a cyber-physical structure similar to that of a typical …
Remedial pilot main protection scheme for transmission line independent of data synchronism
For those protective relays highly dependent on common centralized timing synchronization,
the threat of loss of data synchronism, eg, due to cyber-attack, cannot be ignored. In this …
the threat of loss of data synchronism, eg, due to cyber-attack, cannot be ignored. In this …
Resilient protection of medium voltage DC microgrids against cyber intrusion
Differential current protection has been a reliable approach for line protection in DC
systems. However, due to its dependence on communication for terminal current …
systems. However, due to its dependence on communication for terminal current …
The effect of time synchronization error in LAN-based digital substation
KJ Son, TG Chang, SH Kang - Sensors, 2019 - mdpi.com
In this paper, the effect of time synchronization error on protection algorithms are studied for
the usage of the LAN-based collaborative protection. In order to derive the effect of time …
the usage of the LAN-based collaborative protection. In order to derive the effect of time …