Clinical and radiographic outcomes at 25-30 years of a hip stem fully coated with hydroxylapatite

L Jacquot, MP Bonnin, A Machenaud… - The Journal of …, 2018 - Elsevier
Background Little is known about the survival of total hip arthroplasty implants with bioactive
coatings beyond the first 20 years. The authors aimed to report survival of a tapered hip stem …

Modern revision femoral stem designs have No difference in rates of subsidence

S Yacovelli, J Ottaway, S Banerjee… - The Journal of …, 2021 - Elsevier
Background Both modular and monoblock tapered fluted titanium (TFT) stems have gained
popularity over fully porous-coated cylindrical (FPCC) femoral stem designs, but limited data …

Is there a difference in perioperative mortality between cemented and uncemented implants in hip fracture surgery?

M Hossain, JG Andrew - Injury, 2012 - Elsevier
INTRODUCTION: Although cemented implants have proven beneficial over uncemented
implants for treatment of displaced sub-capital proximal femoral fractures, there are …

Survival and clinical outcomes at 30 to 35 years following primary total hip arthroplasty with a cementless femoral stem fully coated with hydroxyapatite

L Jacquot, A Machenaud, MP Bonnin… - The Journal of …, 2023 - Elsevier
Background The purpose of the present study was to update and report clinical outcomes
and survival of primary total hip arthroplasty using a cementless double-tapered titanium …

Varus will have varus; a radiological study to assess and predict varus stem placement in uncemented femoral stems

CG Murphy, MP Bonnin, AH Desbiolles… - Hip …, 2016 - journals.sagepub.com
Background Varus inclination of the uncemented stem is not necessarily a technical error.
The proximal femoral anatomy of hips with a coxa vara deformity frequently predisposes …

Hemiarthroplasty using cemented or uncemented stems of proven design: a comparative study

G Grammatopoulos, HA Wilson… - The bone & joint …, 2015 - boneandjoint.org.uk
National Institute of Clinical Excellence guidelines state that cemented stems with an
Orthopaedic Data Evaluation Panel (ODEP) rating of> 3B should be used for …

[HTML][HTML] Use of the Corail stem for revision total hip arthroplasty: evaluation of clinical outcomes and cost

TJ Wood, M Alzahrani, JD Marsh… - canadian Journal of …, 2019 - ncbi.nlm.nih.gov
Background With the growing number of total hip arthroplasty (THA) procedures performed,
revision surgery is also proportionately increasing, resulting in greater health care …

Subsidence and perioperative periprosthetic fractures using collarless hydroxyapatite-coated stem for displaced femoral neck fractures according to Dorr type

JH Song, WL Jo, KH Lee, YJ Cho… - Journal of …, 2019 - journals.sagepub.com
Background: Hydroxyapatite (HA)-coated stem has been introduced to decrease
complications and eventually achieve quicker implant ingrowth and long-term stability. The …

[HTML][HTML] Early complications following cemented modular hip hemiarthroplasty

NPT Sullivan, AW Hughes, RL Halliday… - The open …, 2015 - ncbi.nlm.nih.gov
Method: A series of 459 consecutive patients (May 2006-June 2009) treated with a JRI
hemiarthroplasty with a minimum of one-year (1-4years) follow-up were evaluated. Data …

High incidence of intraoperative fractures with a specific cemented stem following intracapsular displaced hip fracture

M Laflamme, M Angers, J Vachon, V Pomerleau… - The Journal of …, 2020 - Elsevier
Background To reduce costs of orthopedic implants, the government decided to standardize
implants used across different specialties in a group of hospitals located in the same …