Outcomes of cataract surgery in patients with uveitis: a systematic review and meta-analysis
Purpose To critically assess the evidence base regarding outcomes following cataract
surgery in uveitic cases. Design Systematic evidence-based review and meta-analysis …
surgery in uveitic cases. Design Systematic evidence-based review and meta-analysis …
[图书][B] Bio-implant interface: improving biomaterials and tissue reactions
JE Ellingsen, SP Lyngstadaas - 2003 - taylorfrancis.com
Achieving good clinical outcomes with implanted biomaterials depends upon achieving
optimal function, both mechanical and biological, which in turn depends upon integrating …
optimal function, both mechanical and biological, which in turn depends upon integrating …
Biocompatibility of hydrophilic acrylic, hydrophobic acrylic, and silicone intraocular lenses in eyes with uveitis having cataract surgery: Long-term follow-up
C Abela-Formanek, M Amon, G Kahraman… - Journal of Cataract & …, 2011 - Elsevier
PURPOSE: To evaluate the long-term uveal and capsular biocompatibility of 5 intraocular
lenses (IOLs) in eyes with uveitic cataract. SETTING: Department of Ophthalmology, Medical …
lenses (IOLs) in eyes with uveitic cataract. SETTING: Department of Ophthalmology, Medical …
Phacoemulsification in eyes with a small pupil
A Vasavada, R Singh - Journal of Cataract & Refractive Surgery, 2000 - Elsevier
PURPOSE: To evaluate the intraoperative difficulties and long-term outcome of
phacoemulsification through a small pupil using minimal iris manipulation. SETTINGS …
phacoemulsification through a small pupil using minimal iris manipulation. SETTINGS …
Phacoemulsification with intraocular lens implantation in cases of pars planitis
Purpose: To analyze the results of phacoemulsification cataract surgery with implantation of
posterior chamber intraocular lenses (IOLs) of different biomaterials in eyes with pars …
posterior chamber intraocular lenses (IOLs) of different biomaterials in eyes with pars …
Inflammatory cell adhesion and surface defects on heparin-surface-modified poly (methyl methacrylate) intraocular lenses in diabetic patients
D Tognetto, G Ravalico - Journal of Cataract & Refractive Surgery, 2001 - journals.lww.com
Purpose: To evaluate the incidence of surface scratches on heparin-surface-modified (HSM)
poly (methyl methacrylate)(PMMA) intraocular lenses (IOLs) and the possible influence of …
poly (methyl methacrylate)(PMMA) intraocular lenses (IOLs) and the possible influence of …
The inert-bioactivity conundrum
DF Williams - The Implant Tissue Interface, 2003 - books.google.com
This chapter is primarily concerned with the analysis of the requirements of long-term
implantable devices, their biocompatibility, and especially with the implicit material selection …
implantable devices, their biocompatibility, and especially with the implicit material selection …
Pit defects on the anterior surface of hydrophilic foldable intraocular lenses
D Tognetto, L Toto, G Ravalico - Journal of Cataract & Refractive …, 2000 - journals.lww.com
A series of pits varying in depth and size appeared on the anterior surface of hydrogel
intraocular lenses (IOLs) soon after they were implanted. In all cases, the pits increased in …
intraocular lenses (IOLs) soon after they were implanted. In all cases, the pits increased in …
[HTML][HTML] The outcomes of cataract surgery in eyes with Fuchs uveitis
Y Özdamar Erol, K Özdemir Yalçınsoy… - Journal of Ophthalmic …, 2023 - Springer
Background To evaluate clinical results in eyes undergoing phacoemulsification intraocular
lens (IOL) implantation due to Fuchs, uveitis (FU) related complicated cataract. Methods Post …
lens (IOL) implantation due to Fuchs, uveitis (FU) related complicated cataract. Methods Post …