[HTML][HTML] Tensile behaviour of soda-lime-silica glass and the significance of load duration–A literature review

MJ Meyland, JH Nielsen, C Kocer - Journal of Building Engineering, 2021 - Elsevier
Soda-lime-silica glass is a widely used material in society today and its strength over various
loading times is of major engineering concern. This paper reviews studies from the …

Fragility functions for architectural nonstructural components

S Bianchi, S Pampanin - Journal of structural engineering, 2022 - ascelibrary.org
Nonstructural components typically are not designed for seismic loads, yet their behavior
can affect the postearthquake building functionality significantly. Nonstructural damage …

Towards a reliable seismic assessment of rocking components

D D'Angela, G Magliulo, E Cosenza - Engineering Structures, 2021 - Elsevier
The paper addresses the reliability of the existing shake table testing protocols for
assessment of the seismic response of freestanding, ie unanchored, components meant as …

Comparative analysis of the PCM application according to the building type as retrofit system

JH Park, J Jeon, J Lee, S Wi, BY Yun, S Kim - Building and Environment, 2019 - Elsevier
It is necessary to reduce the environmental load by reducing the energy consumption in the
building sector. As one of the preferred methods, phase change materials (PCMs) are …

Numerical modelling of global/local mechanisms and sensitivity analysis for the seismic vulnerability assessment of glass curtain walls

N Cella, C Bedon - Engineering Structures, 2024 - Elsevier
Façades represent complex and vulnerable components for buildings, due to the intrinsic
fragility and brittleness of glass, and require specific design and calculation tools, both for …

Shaking table test on seismic response of a planar irregular structure with differential settlements of foundation

F Xu, C Bao, X Ma, Y Zhang, KS Lim, Y Zhang, H Wang… - Structures, 2022 - Elsevier
The differential settlement of the foundation not only causes the degradation of the static
performance of structures, but also affects the seismic performance. To investigate the …

Considerations on efficient procedural steps for seismic capacity assessment and diagnostics of historic structural glass systems

C Bedon, MV Santi, M Fasan - Soil Dynamics and Earthquake Engineering, 2022 - Elsevier
Structural designers are nowadays supported by standards and guidelines to optimize the
mechanical performance and safety level of glass load-bearing elements and assemblies in …

A new damage identification approach of HFSGCW based on LDV and wavelet packet band energy method

H Zheng, D He, T Guo, Z Chen - Journal of Building Engineering, 2024 - Elsevier
This study introduces a damage assessment system and a pivotal detection technique for
hidden frame-supported glass curtain wall (HFSGCW) structural sealant. The vibration …

Shaking table tests of a nonstructural freestanding object with variable center of gravity

B Huang, Z Hu, C Tang, X Guan, W Lu - Soil Dynamics and Earthquake …, 2024 - Elsevier
Freestanding objects have endured seismic damage during major historical earthquakes,
but their seismic performance is not fully understood yet. A steel frame was constructed with …

A framework for estimating immediate interdependent functionality reduction of a steel hospital following a seismic event

EM Hassan, H Mahmoud - Engineering Structures, 2018 - Elsevier
Functionality of an infrastructure is its ability to provide its intended services. Maintaining an
acceptable level of infrastructure functionality, particularly for critical infrastructure, following …