Noise and non-neuronal contributions to the BOLD signal: applications to and insights from animal studies

SD Keilholz, WJ Pan, J Billings, M Nezafati, S Shakil - Neuroimage, 2017 - Elsevier
The BOLD signal reflects hemodynamic events within the brain, which in turn are driven by
metabolic changes and neural activity. However, the link between BOLD changes and …

Reference‐free single‐pass EPI N yquist ghost correction using annihilating filter‐based low rank H ankel matrix (ALOHA)

J Lee, KH Jin, JC Ye - Magnetic resonance in medicine, 2016 - Wiley Online Library
Purpose MR measurements from an echo‐planar imaging (EPI) sequence produce Nyquist
ghost artifacts that originate from inconsistencies between odd and even echoes. Several …

Dual‐polarity GRAPPA for simultaneous reconstruction and ghost correction of echo planar imaging data

WS Hoge, JR Polimeni - Magnetic resonance in medicine, 2016 - Wiley Online Library
Purpose The purpose of this study was to seek improved image quality from accelerated
echo planar imaging (EPI) data, particularly at ultrahigh fields. Certain artifacts in EPI …

Navigator-free EPI ghost correction with structured low-rank matrix models: New theory and methods

RA Lobos, TH Kim, WS Hoge… - IEEE transactions on …, 2018 - ieeexplore.ieee.org
Structured low-rank matrix models have previously been introduced to enable
calibrationless MR image reconstruction from sub-Nyquist data, and such ideas have …

Improved least squares MR image reconstruction using estimates of k‐Space data consistency

KM Johnson, WF Block, SB Reeder… - Magnetic resonance …, 2012 - Wiley Online Library
This study describes a new approach to reconstruct data that has been corrupted by
unfavorable magnetization evolution. In this new framework, images are reconstructed in a …

Partial Fourier transform reconstruction for single‐shot MRI with linear frequency‐swept excitation

Y Chen, J Li, X Qu, L Chen, C Cai, S Cai… - Magnetic resonance …, 2013 - Wiley Online Library
A novel image encoding approach based on linear frequency‐swept excitation has been
recently proposed to overcome artifacts induced by various field perturbations in single‐shot …

Robust EPI Nyquist ghost removal by incorporating phase error correction with sensitivity encoding (PEC‐SENSE)

VB Xie, M Lyu, Y Liu, Y Feng… - Magnetic resonance in …, 2018 - Wiley Online Library
Purpose The existing approach of Nyquist ghost correction by parallel imaging in echo
planar imaging (EPI) can suffer from image noise amplification. We propose a method that …

k‐Space deep learning for reference‐free EPI ghost correction

J Lee, Y Han, JK Ryu, JY Park… - Magnetic Resonance in …, 2019 - Wiley Online Library
Purpose Nyquist ghost artifacts in echo planar imaging (EPI) are originated from phase
mismatch between the even and odd echoes. However, conventional correction methods …

Learning from synthetic data for reference‐free Nyquist ghost correction and parallel imaging reconstruction of echo planar imaging

L Dai, Q Yang, J Lin, Z Zhou, P Zhang, S Cai… - Medical …, 2023 - Wiley Online Library
Background Echo planar imaging (EPI) suffers from Nyquist ghost caused by eddy currents
and other non‐ideal factors. Deep learning has received interest for EPI ghost correction …

Model‐based iterative reconstruction for single‐shot EPI at 7 T

U Yarach, MH In, I Chatnuntawech… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose To describe a model‐based reconstruction strategy for single‐shot echo planar
imaging (EPI) that intrinsically accounts for k‐space nonuniformity, Nyquist ghosting, and …